Download LENGTH-ANGLE-RADIUS-LOAD INDICATING SYSTEM

Transcript
6
4.3
MENTOR EI65 SERVICE MANUAL
ANTI TWO BLOCK PROBLEM
PROBLEM: Function of Anti-Two-Block System is faulty.
START
Check to see whether or not crane is in two-block condition.
Correct?
No
Lower hook down into safe position
Yes
Check weight position. Refer to Operator’s Handbook Section 5. Pre-Operation
Inspection, item 1, 2, and 3 for switch weight positions for the main boom and extension.
Correct?
No
Position the weight properly
Yes
Check the A2B circuit at the boom tip junction box.
With power off, measure A2B signal boom tip junction box.
With the bypass plugs and switch weight in position the ohm meter reads 4.7K
ohms.
Refer to Installation Manual for system wiring diagram.
Correct?
No
Replace Anti-Two-Block switch
Yes
Next Page
© Hirschmann Automation and Control Rev. - 02/02/10