Download batteries
Transcript
BATTERY SERVICE 4. To rechargebattery,insert plug into State of ChargeSpecificGravityReading trickle chargerinto charger jack.Plug 1.265 110 volt AC outlet,allowingbatteryto ChargedFully 75% Charged 1.225 charge approximately ten hours. 50% Charged 1.190 25% charged 1.155 Discharged 1.120 NOTE 1. Remove caps from battery using screwdriver. Do not chargeforlongerthan 48 hours, as extended charge times will cause electrolyte to evaporate leaving a dry and damaged battery. Allowbattery to stand for some time after filling before placing on charge 2. Placehydrometer(part no. 681007) (see figure 3) into each cell. Squeeze bulb on top of hydrometer and release slowly. 5. When charging battery use only the LAWN-BOY chargersupplied with the mower. Do not charge at a rate exceeding 1 amp. 3. Number of balls floatingindicatescondition of battery. If any cell reads two ballsor less floating, rechargebattery for 10 hours. Servicing Specific Gravity of Battery When using a hydrometer that showsspecific gravity,thefollowingspecificgravity numbers (when measured at 80°F (26.7°C) indicate the approximate battery charge condition. FIGURE 3 SERVICE BULLETIN REFERENCES 13-3 REVISED 1977