SERVICE DATA SHEET 242292200 PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0° CONTROL SETTING Type A with Run / Start Capacitor Operating Time Freezer Temperature Refrigerator Temperature 65°F (18°C) Ambient 90°F (32°C) Ambient 90 to 100% 100% -5° to 2°F (-20° to -17°C) -1° to 3°F (-18° to -16°C) ICE & WATER - AUTOMATIC DEFROST 34° to 39°F (1° to 4°C) 34° to 39°F (1° to 4°C) Low Side Pressure -2 to 6 psig ( -14 to 41 kPa) -2 to 6 psig (-14 to 41 kPa) High Side Pressure (last 1/3 cycle) 85 to 105 psig (586 to 724 kPa) 120 to 135 psig (827 to 931 kPa) Wattage (last 1/3 cycle) 30 to 50 50 to 70 Amps (running) .4 to .8 .7 to .9 Base Voltage 115 vac (127 vac max) 26’ & 28’ SD, 23’ CD Thermostat Cut-in Cut-out 25°F (-4°C) 47°F (8°C) Heater Watts FF -- OP OP -- -- SH Ohms 500 26.5 Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time. CONDENSER FAN MOTOR SH -- SY CF SY Watts RPM Amps 3.1 1100 CW Opposite Shaft 0.03 Running CE 115 vac (127 vac max) Thermostat Opens at 48°F ( 9°C), Closes at 15° F ( -9°C) Heater Voltage 115 vac Display Interpretation Mode FZ Activate/Deactivate (press for up to 10 sec. simultaneously) FF Open FF Thermistor Manual Defrost d F + and - / same to deactivate Open FZ Thermistor Display / Showroom 77 77 ٨ and - / Power-on-Reset (POR) Sb Sb ٧ and + / same to deactivate Shorted FF Thermistor Sabbath Shorted FZ Thermistor System Diagnostic No FF or FZ dis٨ and ٧/ + to deactivate play, all UI LEDs on. Notes: UI to Main Control Board communication • Always check for pin back-outs, pinched or damaged wires before replacing components. failure; on start up • Determine whether failure is caused by the component, main control board or UI Main Control wiring. Contact TID before replacing main control board. Board communication • Refer to Service Manual for additional information. error; after a period in operation SY EF FREEZER ICE MAKER SPECIFICATIONS Electrical Special Modes Display FZ Evaporator Fan Failure Variable Capacity Compressor (VCC) Diagnostics (select models) If test 38 fails, diagnose as follows: FREEZER ICE MAKER CONNECTOR PLUG CONNECTIONS Wire Number Wire Color Connects to: 1 Green / Yellow Ground 2 Yellow Water Valve 3 Black Line 4 Light Blue Neutral → Check at the connector from the power cord harness into the inverter board, located in the machine compartment. (PUR and WHT wires) → yes no • → yes Is Inverter Board receiving 10-15 VAC and 1-5 VDC from Main Control Board? Is Inverter Board receiving 115 VAC from power supply? • Check at Inverter Board on Compressor (BLK and RED wires) Remove inverter box from the compressor and check resistance across compressor winding pairs as shown. Is resistance across all winding pairs equal? no Check voltage supply. Check and repair power cord harness wiring and connections. → yes Check connections from Inverter Board to Compressor Are connections from Inverter Board to Compressor intact? no no Replace Compressor and Inverter Board. → Check at Main Control Board (BLK/WHT and RED/BLK wires) no Is Main Control Board sending 10-15 VAC and 1-5 VDC to Inverter Board? Identify and repair damaged wires or poor connections between Inverter Board and Compressor. yes Replace Main Control Board. yes Identify and repair damaged wires or poor connections between Main Control Board and Inverter Board. Replace Inverter Board VCC Resistance Check Check resistance between terminals 1 and 2, 2 and 3, 3 and 1. If all resistances are equal, compressor is operative. FREEZER ICE MAKER INFORMATION (Where Applicable) Test Cycling: Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. Water Fill Adjustment All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner. Press + for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity. Note: Silence alarm. To activate test: Passing result -- First Screen -- All LED lights on UI illuminated -- Second Screen -- All segments on UI temperature displays illuminated -- Third Screen -- Blank UI display, no lights illuminated, no shadowing; “-” and “+” blinking on FF display side to show location. 28 Dispenser Paddle Press disp. paddle “on” on UI when depressed; “off” when released 1* Standard Compressor Set Compressor running when “on”; stopped when “off” 2 Defrost Heater Set Defrost limit switch must be closed; verify “CL” in test 26. Feel for heat from defrost heater when “on”. If “OP” in test 26, heater will not activate. 3 FF Light Set With FF door open, FF lights on when “on”; off when “off” 8 Water Valve (Dispenser) Set FF door must be closed. Be prepared to collect water at dispenser. Water dispenses when “on”; stops when “off” 9 FZ Light Set With FZ door open, FZ lights on when “on”, off when “off” 10 Auger Motor Set FF door must be closed. Motor running when “on”; motor stopped when “off” 11 Cube/Crush Solenoid Set FF door must be closed. Do not leave solenoid in activated state. Solenoid activated when “on”; deactivated when “off” 41* Perfect Temp Drawer (PTD) Set PTD UI illuminated when “on”, off when “off” 12* VCC Condenser Fan Set Fan running when “on”; stopped when “off” 38* VCC Compressor Set Compressor running when “on”; stopped when “off” 15 Evaporator Fan Set Fan running for minimum of 10 sec. when “LO” or “HI”; stopped when “off”. Feedback failure if fan starts but runs less than 10 sec. Listen for speed change from “LO” to “HI”. 36 Ice Chute Door Depress ice chute door or set “OP” on UI when manually opened; “CL” when closed. Or, using “power on-off”, “OP” on UI when solenoid activated, “CL” when deactivated 22 Damper Set With inspection mirror, observe damper open when “OP”; closed when “CL” 23 FF Door Open/close FF door “CL” on UI when door closed; “OP” when open 24 FZ Door Open/close FZ door “CL” on UI when door closed; “OP” when open 26 Defrost Limit Switch Activates automatically “CL” on UI when closed; “OP” when open 29 FF Thermistor Mid-level Activates automatically UI shows temperature sensed by FF thermistor; pass if within 10°F of temperature measured with gauge at mid-level FF thermistor location. “OP-” if open; “SH-” if short 30 FZ Thermistor Activates automatically UI shows temperature sensed by FZ thermistor; pass if within 10°F of temperature measured with gage at FZ thermistor location. “OP” if open; “SH” if short 33 Ambient Thermistor @ Main Board Activates automatically UI shows temperature sensed at main board; pass if within +20°F/10°F of temperature measured with gauge at main board location. “OP” if open; “SH” if short 35* FF Thermistor Upper-Level Activates automatically UI shows temperature sensed by upper level FF thermistor; pass if within 10°F of temperature measured with gauge at upper-level FF thermistor location. “OP¯” if open; “SH¯” if short 34* Ambient Thermistor @ UI Activates automatically UI shows temperature sensed at UI; pass if within +20°F/-10°F of temperature measured with gauge at UI location. “OP” if open; “SH” if short 0- Firmware Parameters Set Displays digit sequence; record 2- Main Board Firmware Set Displays digit sequence; record 4- UI Firmware Set Displays digit sequence; record Motor Gear TU R N CAUTION Water Fill Volume: The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked. Deactivate: Test IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION. Error Codes Press ٨ and ٧ for up to 10 sec. simultaneously. • Tests marked with “*” may not be applicable to this unit and will not be displayed in System Diagnostic Mode. • Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through. • View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests. • Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests. BOTTOM FREEZER - R134a DEFROST SPECIFICATIONS Cabinet Size System Diagnostic Mode Activate: Mounting Plate Screws Mounting Plate Screw IMPORTANT SAFETY NOTE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance. IMPORTANT Timing Gear If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured. DAMPER MOTOR M OUT 1A J4B-6 OUT 2A J4B-1 OUT 1B J4B-2 OUT 2B J4B-3 NTC - FF J4A-3 J4A-9 NTC - FZR J4A-5 J4A-11 REFRIGERATOR LIGHTS J2-12 J3-8 J3-11 LINE DEFROST HEATER 5 LINE COM VS VCC COMPRESSOR J4A-7 UI A M J4B-5 J4A-13 J3-2 J3-1 CONDENSER FAN M LATCH 1 2 3 2 1 RED 5 4 1 LEFT DOOR CONNECTION 3 1 7 7 RIGHT DOOR CONNECTION GRY/BLK WHT/YEL 1 2 BLK/YEL 3 GRY/BLK 4 BRN/YEL RED/YEL 5 6 4 3 WHT/YEL BLK/YEL A2 2 BRN/YEL 1 RED/YEL B1 A1 12 13 14 15 6 7 8 9 10 1 2 3 4 5 4 5 6 7 8 9 10 11 12 2 13 3 14 15 CATCH 1 DEFROST HEATER J1 GRN/YEL BLK LT. BLU BLK/WHT 12V+ BLK RED/BLK 12V- RED (L) PUR 1 2 3 4 WHT/BLU WHT/BLU WHT/BRN WHT/BRN 1 2 3 4 WHT/BLU 4 3 2 1 4 3 2 1 WHT/BRN WHT/BRN WHT/BLU WHT/BLU WHT/BRN WHT/BRN WHT/BLU WHT/BLU WHT/BRN 4 WHT/BRN 3 WHT/BLU 2 WHT/BLU 1 1 2 3 4 WHT/BLU WHT/RED WHT/BRN WHT/GRN RIBBED 7 8 9 1 2 3 LT. BLU/BLK FRESH FOOD COMPARTMENT CONNECTION AT CONTROL BOARD ICE MAKER FILL VALVE J3-9 NEUTRAL FZ ICE MAKER OUTPUT J3-4 MULLION HEATER LED FREEZER ICE MAKER ERF2500++ ERROR CODES: FREEZER DISPLAY: "OP" OR "2" - FREEZER THERMISTOR "OPEN" "SH" OR "3" - FREEZER THERMISTOR "SHORTED" FRESH FOOD DISPLAY: "OP" OR "2" - FRESH FOOD THERMISTOR "OPEN" "SH" OR "3" - FRESH FOOD THERMISTOR "SHORTED" BOTH DISPLAYS: "SY CE" - COMMUNICATION ERROR "SY CF" - COMMUNICATION LOST ERROR "SY EF" - EVAPORATOR FAN ERROR LED RG-3 RG-4 LED LED RG-2 RG-6 LED LED WHT/BRN RG-1 RG-7 WHT/BRN WHT/BRN WHT/BLU WHT/BLU 4 3 2 1 WHT/BRN WHT/BRN WHT/BLU WHT/BLU 4 3 2 1 +12V J2-1 GND J2-3 RG-1 RG-2 LED POWER PCBA RG-3 (N) WHITE REFRIGERATOR LEDS RG-4 RG-5 VARIABLE SPEED COMPRESSOR/ INV. RG-6 1 8 2 9 3 10 4 GRY/WHT 11 5 GRY/WHT 12 6 BRN/WHT 13 DK.BLU/WHT 7 14 YEL/WHT FREEZER CONNECTION AT CONTROL BOARD GRY/BLK GRY/BLK 12 BRN BLK 11 GRY/WHT 10 GRY/WHT 9 8 YEL YEL/PNK 7 BLU/WHT 6 YEL/WHT 5 4 LT. BLU 3 YEL/RED BRN/WHT 2 RED/WHT 1 GRY/WHT GRY/WHT YEL/PNK YEL/RED BLK/ORN BLK 12 9 4 1 J4A J3 MAIN BOARD 4 12 1 9 BLK/YEL BRN/YEL RED/WHT WHT/YEL RED/YEL 1 4 2 5 3 6 J4B J2 BRN BLU YEL RED J1 1 1 J9A 1 RED 2 WHT 3 BLK 1 LT. BLU BLK 3 2 GRN/YEL 4 4 3 2 1 RG-7 WHT/GRN WHT/GRN WHT/RED WHT/RED COND. FAN +12V J2-2 GND J2-4 FZ-1 FZ-2 16 8 YEL/RED 15 7 14 LT. BLU BLK/PNK 6 13 5 12 4 LT.BLU/BLK 11 YEL/RED 3 BLK/ORN 10 YEL 2 RED/BLK 9 YEL 1 BLK/WHT 12 YEL/BLK 6 YEL/PNK 11 5 10 4 9 3 8 RED 2 7 1 BRN 4 WHT/GRN 3 2 WHT/RED 1 SPLICE 3 2 FRZR FAN (DC) +5V RESET_ FLASH BKGD / MSJ GROUND 12 VDC (120V AC REF.) 1 FREEZER DOOR SWITCH (DOOR OPEN) LED 4 5 6 CATCH LATCH LT. BLU 3 6 9 2 5 8 1 4 7 9 6 3 8 5 2 7 4 1 COMPRESSOR GROUND GROUND ATTACHED TO CABINET BEHIND LEFT ROLLER FREEZER THERMISTOR JF-1 JF-2 JF-3 JF-4 J2 RG-5 4 COIL COVER GROUND LED LIGHT WIRING LED POWER SUPPLY DEFROST THERM. ICE MAKER (SEE ICE MAKER DIAGRAM) ASSY_OUT ASSY__IN +5V GROUND LINE LATCH 11 COMPARTMENT BLU J8-5 J8-6 J8-7 J8-8 J3-3 BLK 15 14 GRY/BLK 13 GRY/BLK 12 RED/YEL 11 WHT 10 9 WHT/YEL 8 BRN/YEL 7 6 BLK/YEL RED 5 4 3 LT. BLU 2 YEL/BLK 1 FREEZER VEE (+12) COMM GROUND DAMPER MOTOR 9 1 2 FRESH FOOD CONNECTION IN MACHINE COMPARTMENT RIGHT DOOR GROUND J9A-1 J9A-2 J9A-3 7 8 RIGHT DOOR HINGE GROUND FLIP MULLION HEATER B2 1 2 3 4 LT. BLU/BLK LT. BLU 3 LINE J3-10 LT. BLU 1 2 LT. BLU/BLK GRN/YEL LT. BLU/WHT J2-1 IM WATER SENSE GRY/BLK 3 9 9 GRY/BLK AIR TOWER CONNECTION MULLION GROUND J1-3 FREEZER LIGHTS ERF2500++ FRESH FOOD THERMISTOR YEL/BLK YEL/RED J2 BLK WHT NEUTRAL GROUND LINE NON-RIBBED 3 NEUTRAL 1 1 USER INTERFACE BOARD J1-1 J3-9 J4A-14 5 CATCH ISOLATED FG VCC(+12) LEFT DOOR HINGE GROUND NEUTRAL G5LE RELAY DC EVAPORATOR FAN LEFT DOOR GROUND J2-1 DEFROST THERM. CAB-DOOR CONNECTIONS FZR DOOR SW. SENSE J2-6 NTC - AMBIENT NEUTRAL REFRIGERATOR DOOR OPENING IS DETERMINED BY MAGNETIC SWITCH ON USER INTERFACE REFRIGERATOR CONTROL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 BLK RED BLK/WHT YEL LT. BLU/BLK GRN/YEL LT. BLU YEL/BLK RED/BLK BLK/PNK FZ-2 GREEN I/M WATER VALVE YEL BROWN MAIN WATER VALVE LED FZ-1 LED FREEZER LEDS FREEZER SWITCH (120V AC) FRESH FOOD SWITCH (120V AC) NEUTRAL J1-4 J1-3 J1-1 TYPICAL LED CONNECTOR 1 1 MACHINE COMPARTMENT CONNECTION AT CONTROL BOARD J3 J2 J1 2 5 1 2 6 14 10 3 6 3 5 11 8 16 7 15 4 2 4 10 9 5 13 11 4 2 8 4 12 12 5 1 7 3 11 13 6 2 10 14 7 3 J4B 1 9 1 6 12 J4A 8 3 1 4 9 Wire Diagram 242292801