Download Wiring Diagram

Transcript
SERVICE DATA SHEET
242292200
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°
CONTROL SETTING
Type A with Run / Start
Capacitor
Operating Time
Freezer Temperature
Refrigerator Temperature
65°F (18°C) Ambient
90°F (32°C) Ambient
90 to 100%
100%
-5° to 2°F (-20° to -17°C)
-1° to 3°F (-18° to -16°C)
ICE & WATER - AUTOMATIC DEFROST
34° to 39°F (1° to 4°C)
34° to 39°F (1° to 4°C)
Low Side Pressure
-2 to 6 psig ( -14 to 41 kPa)
-2 to 6 psig (-14 to 41 kPa)
High Side Pressure (last 1/3
cycle)
85 to 105 psig (586 to 724 kPa)
120 to 135 psig (827 to 931
kPa)
Wattage (last 1/3 cycle)
30 to 50
50 to 70
Amps (running)
.4 to .8
.7 to .9
Base Voltage
115 vac (127 vac max)
26’ & 28’ SD, 23’ CD
Thermostat
Cut-in
Cut-out
25°F (-4°C)
47°F
(8°C)
Heater
Watts
FF
--
OP
OP
--
--
SH
Ohms
500
26.5
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run
time.
CONDENSER FAN MOTOR
SH
--
SY
CF
SY
Watts
RPM
Amps
3.1
1100 CW Opposite Shaft
0.03 Running
CE
115 vac (127 vac max)
Thermostat
Opens at 48°F ( 9°C), Closes at 15° F ( -9°C)
Heater Voltage
115 vac
Display
Interpretation
Mode
FZ
Activate/Deactivate
(press for up to 10 sec. simultaneously)
FF
Open FF Thermistor Manual Defrost
d
F
+ and - / same to deactivate
Open FZ Thermistor Display / Showroom
77
77
٨ and - / Power-on-Reset (POR)
Sb
Sb
٧ and + / same to deactivate
Shorted FF Thermistor
Sabbath
Shorted FZ Thermistor
System Diagnostic
No FF or FZ dis٨ and ٧/ + to deactivate
play, all UI LEDs on.
Notes:
UI to Main Control
Board communication • Always check for pin back-outs, pinched or damaged wires before replacing
components.
failure; on start up
• Determine whether failure is caused by the component, main control board or
UI Main Control
wiring. Contact TID before replacing main control board.
Board communication
• Refer to Service Manual for additional information.
error; after a period
in operation
SY
EF
FREEZER ICE MAKER SPECIFICATIONS
Electrical
Special Modes
Display
FZ
Evaporator Fan
Failure
Variable Capacity Compressor (VCC) Diagnostics (select models)
If test 38 fails, diagnose as follows:
FREEZER ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number
Wire Color
Connects to:
1
Green / Yellow
Ground
2
Yellow
Water Valve
3
Black
Line
4
Light Blue
Neutral
→
Check at the connector from the power cord
harness into the inverter board, located in
the machine compartment.
(PUR and WHT wires)
→
yes
no
•
→
yes
Is Inverter Board receiving 10-15
VAC and 1-5 VDC from Main
Control Board?
Is Inverter Board receiving 115 VAC
from power supply?
•
Check at Inverter Board on
Compressor
(BLK and RED wires)
Remove inverter box from the
compressor and check resistance
across compressor winding pairs as
shown.
Is resistance across all winding
pairs equal?
no
Check voltage supply.
Check and repair power
cord harness wiring and
connections.
→
yes
Check connections from Inverter
Board to Compressor
Are connections from Inverter
Board to Compressor intact?
no
no
Replace Compressor and
Inverter Board.
→
Check at Main Control Board
(BLK/WHT and RED/BLK wires)
no
Is Main Control Board sending
10-15 VAC and 1-5 VDC to
Inverter Board?
Identify and repair damaged
wires or poor connections
between Inverter Board and
Compressor.
yes
Replace Main Control Board.
yes
Identify and repair damaged wires or
poor connections between Main Control
Board and Inverter Board.
Replace Inverter Board
VCC Resistance Check
Check resistance between terminals 1 and
2, 2 and 3, 3 and 1.
If all resistances are equal,
compressor is operative.
FREEZER ICE MAKER INFORMATION
(Where Applicable)
Test Cycling: Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor
gear counterclockwise until holding switch circuit is completed. All
components of ice maker should function to complete the cycle.
Water Fill
Adjustment
All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch
to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive
heat will distort the plastic liner.
Press + for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity.
Note: Silence alarm.
To activate test:
Passing result
--
First Screen
--
All LED lights on UI illuminated
--
Second Screen
--
All segments on UI temperature displays illuminated
--
Third Screen
--
Blank UI display, no lights illuminated, no shadowing; “-” and “+”
blinking on FF display side to show location.
28
Dispenser Paddle
Press disp. paddle
“on” on UI when depressed; “off” when released
1*
Standard
Compressor
Set
Compressor running when “on”; stopped when “off”
2
Defrost Heater
Set
Defrost limit switch must be closed; verify “CL” in test 26.
Feel for heat from defrost heater when “on”.
If “OP” in test 26, heater will not activate.
3
FF Light
Set
With FF door open, FF lights on when “on”; off when “off”
8
Water Valve
(Dispenser)
Set
FF door must be closed.
Be prepared to collect water at dispenser.
Water dispenses when “on”; stops when “off”
9
FZ Light
Set
With FZ door open, FZ lights on when “on”, off when “off”
10
Auger Motor
Set
FF door must be closed.
Motor running when “on”; motor stopped when “off”
11
Cube/Crush
Solenoid
Set
FF door must be closed. Do not leave solenoid in activated state.
Solenoid activated when “on”; deactivated when “off”
41*
Perfect Temp
Drawer (PTD)
Set
PTD UI illuminated when “on”, off when “off”
12*
VCC Condenser
Fan
Set
Fan running when “on”; stopped when “off”
38*
VCC Compressor
Set
Compressor running when “on”; stopped when “off”
15
Evaporator Fan
Set
Fan running for minimum of 10 sec. when “LO” or “HI”; stopped when
“off”. Feedback failure if fan starts but runs less than 10 sec. Listen for
speed change from “LO” to “HI”.
36
Ice Chute Door
Depress ice chute
door or set
“OP” on UI when manually opened; “CL” when closed. Or, using “power
on-off”, “OP” on UI when solenoid activated, “CL” when deactivated
22
Damper
Set
With inspection mirror, observe damper open when “OP”; closed when “CL”
23
FF Door
Open/close FF door
“CL” on UI when door closed; “OP” when open
24
FZ Door
Open/close FZ door
“CL” on UI when door closed; “OP” when open
26
Defrost Limit Switch
Activates automatically
“CL” on UI when closed; “OP” when open
29
FF Thermistor
Mid-level
Activates automatically
UI shows temperature sensed by FF thermistor; pass if within 10°F of
temperature measured with gauge at mid-level FF thermistor location.
“OP-” if open; “SH-” if short
30
FZ Thermistor
Activates automatically
UI shows temperature sensed by FZ thermistor; pass if within 10°F of temperature measured with gage at FZ thermistor location.
“OP” if open; “SH” if short
33
Ambient Thermistor
@ Main Board
Activates automatically
UI shows temperature sensed at main board; pass if within +20°F/10°F of temperature measured with gauge at main board location.
“OP” if open; “SH” if short
35*
FF Thermistor
Upper-Level
Activates automatically
UI shows temperature sensed by upper level FF thermistor; pass if
within 10°F of temperature measured with gauge at upper-level FF
thermistor location. “OP¯” if open; “SH¯” if short
34*
Ambient Thermistor
@ UI
Activates automatically
UI shows temperature sensed at UI; pass if within +20°F/-10°F of temperature measured with gauge at UI location. “OP” if open; “SH” if short
0-
Firmware
Parameters
Set
Displays digit sequence; record
2-
Main Board
Firmware
Set
Displays digit sequence; record
4-
UI Firmware
Set
Displays digit sequence; record
Motor
Gear
TU
R
N
CAUTION
Water Fill Volume: The water fill adjustment screw will change the
fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is
102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the
fill volume must be checked.
Deactivate:
Test
IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.
Error Codes
Press ٨ and ٧ for up to 10 sec. simultaneously.
• Tests marked with “*” may not be applicable to this unit and will not be displayed in System Diagnostic Mode.
• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
• View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.
• Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests.
BOTTOM FREEZER - R134a
DEFROST SPECIFICATIONS
Cabinet Size
System Diagnostic Mode
Activate:
Mounting
Plate
Screws
Mounting
Plate
Screw
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel only. Untrained persons should
not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing
this appliance.
IMPORTANT
Timing
Gear
If any green grounding wires are removed during servicing, they must be returned to their original position
and properly secured.
DAMPER
MOTOR
M
OUT 1A
J4B-6
OUT 2A
J4B-1
OUT 1B
J4B-2
OUT 2B
J4B-3
NTC - FF
J4A-3
J4A-9
NTC - FZR
J4A-5
J4A-11
REFRIGERATOR LIGHTS
J2-12
J3-8
J3-11
LINE
DEFROST HEATER
5
LINE
COM
VS
VCC
COMPRESSOR
J4A-7
UI A
M
J4B-5
J4A-13
J3-2
J3-1
CONDENSER FAN
M
LATCH
1
2
3
2
1
RED
5
4
1
LEFT DOOR
CONNECTION
3
1
7
7
RIGHT DOOR
CONNECTION
GRY/BLK
WHT/YEL
1
2
BLK/YEL
3
GRY/BLK
4
BRN/YEL
RED/YEL
5
6
4
3
WHT/YEL
BLK/YEL
A2
2
BRN/YEL
1
RED/YEL
B1
A1
12
13
14
15
6
7
8
9
10
1
2
3
4
5
4
5
6
7
8
9
10
11
12
2
13
3
14
15
CATCH
1
DEFROST HEATER
J1
GRN/YEL
BLK
LT. BLU
BLK/WHT
12V+ BLK
RED/BLK
12V- RED
(L) PUR
1
2
3
4
WHT/BLU
WHT/BLU
WHT/BRN
WHT/BRN
1
2
3
4
WHT/BLU
4
3
2
1
4
3
2
1
WHT/BRN
WHT/BRN
WHT/BLU
WHT/BLU
WHT/BRN
WHT/BRN
WHT/BLU
WHT/BLU
WHT/BRN 4
WHT/BRN 3
WHT/BLU 2
WHT/BLU 1
1
2
3
4
WHT/BLU
WHT/RED
WHT/BRN
WHT/GRN
RIBBED
7
8
9
1
2
3
LT. BLU/BLK
FRESH FOOD
COMPARTMENT
CONNECTION AT
CONTROL BOARD
ICE MAKER
FILL VALVE
J3-9
NEUTRAL
FZ ICE MAKER OUTPUT
J3-4
MULLION HEATER
LED
FREEZER ICE MAKER
ERF2500++ ERROR CODES:
FREEZER DISPLAY:
"OP" OR "2" - FREEZER THERMISTOR "OPEN"
"SH" OR "3" - FREEZER THERMISTOR "SHORTED"
FRESH FOOD DISPLAY:
"OP" OR "2" - FRESH FOOD THERMISTOR "OPEN"
"SH" OR "3" - FRESH FOOD THERMISTOR "SHORTED"
BOTH DISPLAYS:
"SY CE" - COMMUNICATION ERROR
"SY CF" - COMMUNICATION LOST ERROR
"SY EF" - EVAPORATOR FAN ERROR
LED
RG-3
RG-4
LED
LED
RG-2
RG-6
LED
LED
WHT/BRN
RG-1
RG-7
WHT/BRN
WHT/BRN
WHT/BLU
WHT/BLU
4
3
2
1
WHT/BRN
WHT/BRN
WHT/BLU
WHT/BLU
4
3
2
1
+12V
J2-1
GND J2-3
RG-1
RG-2
LED POWER
PCBA
RG-3
(N) WHITE
REFRIGERATOR LEDS
RG-4
RG-5
VARIABLE SPEED
COMPRESSOR/ INV.
RG-6
1
8
2
9
3
10
4
GRY/WHT 11
5
GRY/WHT
12
6
BRN/WHT 13
DK.BLU/WHT 7
14
YEL/WHT
FREEZER
CONNECTION AT
CONTROL BOARD
GRY/BLK
GRY/BLK
12
BRN
BLK
11
GRY/WHT 10
GRY/WHT 9
8
YEL
YEL/PNK
7
BLU/WHT 6
YEL/WHT 5
4
LT. BLU
3
YEL/RED
BRN/WHT 2
RED/WHT 1
GRY/WHT
GRY/WHT
YEL/PNK
YEL/RED
BLK/ORN
BLK
12
9
4
1
J4A
J3
MAIN BOARD
4
12
1
9
BLK/YEL
BRN/YEL
RED/WHT
WHT/YEL
RED/YEL
1
4
2
5
3
6
J4B
J2
BRN
BLU
YEL
RED
J1
1
1
J9A
1 RED
2 WHT
3 BLK
1 LT. BLU
BLK
3
2 GRN/YEL
4
4
3
2
1
RG-7
WHT/GRN
WHT/GRN
WHT/RED
WHT/RED
COND. FAN
+12V
J2-2
GND J2-4
FZ-1
FZ-2
16
8 YEL/RED
15
7
14 LT. BLU
BLK/PNK
6
13
5
12
4 LT.BLU/BLK
11 YEL/RED
3 BLK/ORN
10
YEL
2 RED/BLK
9
YEL
1 BLK/WHT
12 YEL/BLK
6 YEL/PNK
11
5
10
4
9
3
8
RED
2
7
1
BRN
4
WHT/GRN 3
2
WHT/RED 1
SPLICE
3
2
FRZR
FAN
(DC)
+5V
RESET_ FLASH
BKGD / MSJ
GROUND
12 VDC (120V AC REF.)
1
FREEZER DOOR
SWITCH
(DOOR OPEN)
LED
4
5
6
CATCH
LATCH
LT. BLU
3 6 9
2 5 8
1 4 7
9 6 3
8 5 2
7 4 1
COMPRESSOR
GROUND
GROUND ATTACHED
TO CABINET
BEHIND LEFT ROLLER
FREEZER THERMISTOR
JF-1
JF-2
JF-3
JF-4
J2
RG-5
4
COIL COVER
GROUND
LED LIGHT WIRING
LED POWER
SUPPLY
DEFROST
THERM.
ICE MAKER
(SEE ICE MAKER
DIAGRAM)
ASSY_OUT
ASSY__IN
+5V
GROUND
LINE
LATCH
11
COMPARTMENT
BLU
J8-5
J8-6
J8-7
J8-8
J3-3
BLK 15
14
GRY/BLK 13
GRY/BLK 12
RED/YEL 11
WHT 10
9
WHT/YEL 8
BRN/YEL 7
6
BLK/YEL
RED 5
4
3
LT. BLU
2
YEL/BLK
1
FREEZER
VEE (+12)
COMM
GROUND
DAMPER
MOTOR
9
1
2
FRESH FOOD CONNECTION
IN MACHINE COMPARTMENT
RIGHT
DOOR
GROUND
J9A-1
J9A-2
J9A-3
7
8
RIGHT
DOOR HINGE
GROUND
FLIP MULLION HEATER
B2
1
2
3
4
LT. BLU/BLK
LT. BLU
3
LINE
J3-10
LT. BLU
1
2
LT. BLU/BLK
GRN/YEL
LT. BLU/WHT
J2-1
IM WATER SENSE
GRY/BLK
3
9
9
GRY/BLK
AIR TOWER CONNECTION
MULLION
GROUND
J1-3
FREEZER LIGHTS
ERF2500++
FRESH FOOD THERMISTOR
YEL/BLK
YEL/RED
J2
BLK
WHT
NEUTRAL
GROUND
LINE
NON-RIBBED
3
NEUTRAL
1
1
USER INTERFACE BOARD
J1-1
J3-9
J4A-14
5
CATCH
ISOLATED
FG
VCC(+12)
LEFT
DOOR HINGE
GROUND
NEUTRAL
G5LE RELAY
DC EVAPORATOR FAN
LEFT
DOOR
GROUND
J2-1
DEFROST THERM.
CAB-DOOR
CONNECTIONS
FZR DOOR SW. SENSE
J2-6
NTC - AMBIENT
NEUTRAL
REFRIGERATOR DOOR OPENING IS DETERMINED
BY MAGNETIC SWITCH ON USER INTERFACE
REFRIGERATOR
CONTROL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
BLK
RED
BLK/WHT
YEL
LT. BLU/BLK
GRN/YEL
LT. BLU
YEL/BLK
RED/BLK
BLK/PNK
FZ-2
GREEN
I/M
WATER
VALVE
YEL
BROWN
MAIN
WATER
VALVE
LED
FZ-1
LED
FREEZER LEDS
FREEZER SWITCH (120V AC)
FRESH FOOD SWITCH (120V AC)
NEUTRAL
J1-4
J1-3
J1-1
TYPICAL LED CONNECTOR
1
1
MACHINE COMPARTMENT
CONNECTION AT CONTROL
BOARD
J3
J2
J1
2
5
1
2
6 14
10 3
6
3
5 11
8 16
7 15
4
2
4 10
9
5 13
11 4
2
8
4 12
12 5
1
7
3 11
13 6
2 10
14 7
3
J4B
1
9
1
6 12
J4A
8
3
1
4
9
Wire Diagram 242292801