Download Frigidaire FFHB2740PP Wiring diagram
Transcript
SERVICE DATA SHEET PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0° CONTROL SETTING Type A with Run / Start Capacitor 65°F (18°C) Ambient 90°F (32°C) Ambient 90 to 100% 100% -5° to 2°F (-20° to -17°C) -1° to 3°F (-18° to -16°C) 34° to 39°F (1° to 4°C) 34° to 39°F (1° to 4°C) -2 to 6 psig (-14 to 41 kPa) -2 to 6 psig (-14 to 41 kPa) 85 to 105 psig (586 to 724 kPa) 120 to 135 psig (827 to 931 kPa) Operating Time Freezer Temperature Refrigerator Temperature Low Side Pressure High Side Pressure (last 1/3 cycle) Wattage (last 1/3 cycle) 30 to 50 50 to 70 Amps (running) .4 to .8 .7 to .9 Base Voltage A01870701 ICE & WATER - AUTOMATIC DEFROST ERROR CODES Display DEFROST SPECIFICATIONS Heater Cabinet Size: 27’ & 28’ SD, 22’ CD 26.5 39°F (4°C) Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time. CONDENSER FAN MOTOR 3.1 1100 CW Opposite Shaft 0.03 Running Manual Defrost d F + and - / same to deactivate Open FZ Thermistor Display / Showroom 77 77 ٨ and - / Power-on-Reset (POR) -- SH Shorted FF Thermistor Sabbath Sb Sb ٧ and - / same to deactivate Shorted FZ Thermistor System Diagnostic No FF or FZ display, all UI LEDs on. ٨ and ٧/ + to deactivate UI to Main Control Board communication failure; on start up FFIM Diagnostic Numerical display of first test ٨ and + together to activate / press and hold + to deactivate UI to Main Control Board communication error; after a period in operation Notes: • Always check for pin back-outs, pinched or damaged wires before replacing components. • Determine whether failure is caused by the component, main control board or wiring. Contact TID before replacing main control board. • Refer to Service Manual for additional information. EF 500 -- Activate: 115 vac (127 vac max) Thermostat Opens at 48°F ( 9°C), Closes at 15° F ( -9°C) Heater Voltage 115 vac Evaporator Fan Failure FRESH FOOD ICE MAKER DIAGNOSTIC MODE FREEZER ICE MAKER SPECIFICATIONS Electrical FF Open FF Thermistor SY 135°F (57.2°C) FZ Activate/Deactivate (press for up to 10 sec. simultaneously) -- CE 110°F (43.3°C) Display Mode OP SY Cut-out Interpretation -- CF Ohms SPECIAL MODES OP SY Watts Amps FF SH Cut-out RPM FZ Defrost Thermistor Termination Cut-in Watts IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION. Deactivate: 52C Press ٨ and + temperature pads for up to 10 sec. simultaneously. Press + or - to move forward or backward through tests. CAUTION All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner. FREEZER ICE MAKER INFORMATION Water Fill Volume: The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked. Press disp. paddle “on” on UI when depressed; “off” when released. 46 Humidity Sensor Activates automatically “OP” if open, “SH” if short. AC Heater System: Displays %RH. DC Heater System: “HI” – heater should be on. “Lo” – heater should be off. %RH is displayed when humidity is between “Lo” and “HI” values; heater could be on or off. 47 Dispenser Pocket Heater Press set AC Heater System: “--” ; test not available. DC Heater System: heater on when “on”, off when “off”. 2 Freezer Defrost Heater Press set Freezer defrost heater on when “on”; off when “off”. 3* FF Light (Incandescent Models) Press set FF lights on when “on”; off when “off” 8 Water Valve (Dispenser) Press set FF doors must be closed. Be prepared to collect water at dispenser. Water dispenses when “on”; stops when “off”. 9* FZ Light (Incandescent Models) Press set FZ lights on when “on”, off when “off”. 10 Auger Motor Press set FF door must be closed. Motor running when “on”; motor stopped when “off”. 11 Cube/Crush Solenoid Press set FF door must be closed. Do not leave solenoid in activated state. Solenoid activated when “on”; deactivated when “off”. Press set Compressor running when “on”; stopped when “off”. Press set FF lights on when “on”; off when “off”. 15 Evaporator Fan Press set Stopped when “off”. Listen for speed change from “LO” to “HI”. 20* FZ Light (LED Models) Press set FZ lights on when “on”, off when “off”. 22 Damper Press set With inspection mirror, observe damper open when “OP”; closed when “CL”. 23 FF Door Open/close FF door “CL” on UI when door closed; “OP” when open. 24 FZ Door Open/close FZ door “CL” on UI when door closed; “OP” when open. 26 Ice Maker Defrost Heater Activates automatically Relay is activated automatically. If “CL” is shown, defrost limit switch is closed and heater should be heating up. If “OP” is shown, defrost limit switch is open and heater will not activate. 29 FF Thermistor Activates automatically UI shows temperature sensed by FF thermistor; pass if within 10°F of temperature measured with gauge at FF thermistor location. “OP-” if open; “SH-” if short. 30 FZ Thermistor Activates automatically UI shows temperature sensed by FZ thermistor; pass if within 10°F of temperature measured with gauge at FZ thermistor location. “OP” if open; “SH” if short. 33 Ambient Thermistor @ Main Board Activates automatically UI shows temperature sensed at main board; pass if within +20°F/-10°F of temperature measured with gauge at main board location. “OP” if open; “SH” if short. 34* Ambient Thermistor @UI Activates automatically UI shows temperature sensed at UI; pass if within +20°F/-10°F of temperature measured with gauge at UI location. “OP” if open; “SH” if short. 39 Evaporator Thermistor Activates automatically UI shows temperature sensed by evaporator thermistor; pass if within 10°F of temperature measured with gauge at evaporator thermistor location. “OP” if open; “SH” if short. 45 Ice Maker Mold Thermistor Activates automatically UI shows temperature sensed at ice maker; pass if within +20°F/-10°F of temperature measured with gauge at ice maker mold. “OP” if open; “SH” if short. 0- Firmware Parameters Press set Displays digit sequence; record. 2- Main Board Firmware Press set Displays digit sequence; record. 4- UI Firmware Press set Displays digit sequence; record. Activates automatically FZ display shows temperature sensed by Ice Maker Thermistor. “OP” if open; “SH” if short Press Set Remove ice tray to collect water into a measuring container to measure water fill. If collecting water into ice tray, first perform test 63C to empty ice tray. Remove ice bucket. Allow bail arm to drop freely. Pass if no alarm when tray returns to “home” position. Hold bail arm up. Pass if alarm sounds when tray returns to “home” position. This test runs continuously until another test is selected. Twist Tray Press Set → yes Check at Inverter Board on Compressor (BLK and RED wires) Remove ice bucket. FZ display shows “1” and “GOOD”. → yes Is Inverter Board receiving 10-15 VAC and 1-5 VDC from Main Control Board? Remove inverter box from the compressor and check resistance across compressor winding pairs as shown. Is resistance across all winding pairs equal? → Check at Main Control Board (BLK/WHT and RED/BLK wires) → yes Check connections from Inverter Board to Compressor Are connections from Inverter Board to Compressor intact? no Replace Compressor and Inverter Board. Identify and repair damaged wires or poor connections between Main Control Board and Inverter Board. Mounting Plate Screw Dispenser Paddle FF Light (LED Models) yes N Test Cycling: Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. Blank UI display, no lights illuminated. 28 VCC Compressor Activates automatically Mounting Plate Screws -- 13* Is Main Control Board sending 10-15 VAC and 1-5 VDC to Inverter Board? R Third Screen 38* Passing Result To activate test no TU (Where Applicable) All segments on UI temperature displays illuminated. -- Test Ice Level Sensor Motor Gear -- Flip mullion heater and dispenser pocket heater on when “on”; off when “off” “On” on FZ display when fan activated, “OFF” when deactivated. Water Fill Adjustment Second Screen Fan running when “on”; stopped when “off”. no • All LED lights on UI illuminated. -- Press set Press Set Check voltage supply. Check and repair power cord harness wiring and connections. Passing result -- Press set Is Inverter Board receiving 115 VAC from power supply? • To activate test: First Screen VCC Condenser Fan Evaporator Fan (FFIM) Check at the connector from the power cord harness into the inverter board, located in the machine compartment. (PUR and WHT wires) Test -- Anticondensation Heater Variable Capacity Compressor (VCC) Diagnostics (select models) If test 38 fails, diagnose as follows: → Tests marked with “*” may not be applicable to this unit and will not be displayed in System Diagnostic Mode. Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through. View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests. Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests. 43 58C 63C Press + for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity. Note: Silence alarm. 12 Water Valve 57C Deactivate: Press + for up to 10 sec. FFIM Diagnostic Mode will automatically deactivate after 5 min. of inactivity. NOTE: Silence alarm. Ice Maker Thermistor 55C Press ٨ and ٧ for up to 10 sec. simultaneously. Press + to advance through tests. • • • • BOTTOM FREEZER - R134a 115 vac (127 vac max) Thermal Cutout SYSTEM DIAGNOSTIC MODE Activate: no no Identify and repair damaged wires or poor connections between Inverter Board and Compressor. yes Replace Main Control Board. VCC Resistance Check Check resistance between terminals 1 and 2, 2 and 3, 3 and 1. If all resistances are equal, compressor is operative. Replace Inverter Board IMPORTANT SAFETY NOTE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance. IMPORTANT Timing Gear If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured. 1 5 2 4 J3 3 6 9 10 +12V DC REVERSIBLE 12V DC SIDE FLAPPER MOTOR BLK USER INTERFACE 3 2 1 J4 PIN 3 PIN 4 PIN 5 PIN 3 PIN 4 PIN 5 LH2 RH2 WHT RED 1 2 J9 3 4 AC SIDE GND 2 GRY/WHT 1 AT1 FRESH FOOD SENSOR BLK M 2 2 PIN 4 PIN 7 1 PIN 1 PIN 8 GRN/BLU RED 1 DK. BLU TWIST MOTOR MB1 M BAIL ARM SWITCH TRAY SENSOR IM1 PIN 4 PIN 2 PIN 1 PIN 8 PIN 2 PIN 3 PIN 1 PIN 7 PIN 5 PIN 2 PIN 4 PIN 6 PIN 6 PIN 5 PIN 3 PIN 1 IM2 MC2 GRY/BLK GRY/BLK GRN/BLU DK. BLU WHT RED BLU YEL GREY GREY 1 8 2 3 J7 4 7 5 6 BLK LT. BLU LT. BLU COMM. NEUTRAL +5V DC CAB. GROUND +12V DC LT. BLU 12 VDC GRN/YEL BASE PLATE GROUND BLK PIN 5 1 J1 2 3 +5V DC LT. BLU +5V DC RL4 RL8 +12V DC REVERSIBLE 12V DC +5V DC J2 3 7 4 J3 YEL/RED YEL/BLK U2 6 RED RL9 J3 3 YEL RL7 5 AT1 FLIP MULLION COVER PIN 8 PIN 3 RIGHT HINGE GROUND REFRIGERATOR LIGHTS LT. BLU YEL/BLK PIN 9 1 LT. BLU/BLK LT. BLU BLK SPLICE PIN 9 PIN 6 PIN 1 PIN 1 1 PIN 2 3 RH3 SPLICE PIN 1 RH1 CONDENSER FAN 2 GRN/YEL 2 PIN 6 PIN 4 LT. BLU/BLK LT. BLU/WHT MULLION HEATER FLAPPER & SUMP HEATER 2 1 PIN 2 LH1 TWIST ICEMAKER WATER VALVE TAN DISPENSER WATER VALVE LT. BLU LT. BLU DIODE +5V DC RIGHT DOOR FLANGE LT. BLU PIN 2 LT.BLU/BLK MC1 FREEZER LIGHT 1 MC1 RL5 GRN/YEL 2 YEL/RED +5V DC VARIABLE SPEED COMPRESSOR/ INV. CONTROL SIGNAL RED/BLK BLK/WHT SPLICE TAN GRY/WHT 7 8 9 J6 10 11 12 POWER LT. BLU SPLICE YEL GRY/YEL 1 FREEZER SENSOR IM FAN MOTOR GRY/YEL 2 COMPRESSOR GROUND BLK LINE FREEZER EVAPORATOR SENSOR RIBBED (NEUTRAL) DISPENSER PADDLE DISPENSER LIGHT PIN 1 +12V DC BASE PLATE GROUND FLAPPER POSITION SWITCH PIN 4 +12V DC NON-RIBBED (LINE) POWER CORD MAIN INLET WATER VALVE SPLICE TAN/YEL SPLICE SPLICE DIODE YEL/BLU PIN 1 2 PIN 3 RED/WHT BRN/WHT MB1 RED COMPRESSOR CONTROL SIGNAL BLK RED/BLK 1 BLK/WHT 2 AT1 RED/YEL PIN 6 12V DC DAMPER MOTOR RED/YEL BRN/YEL PIN 5 BRN/YEL BLK/YEL WHT/YEL BLK/YEL PIN 3 WHT/YEL PIN 2 YEL/BLK (COM) YEL/GRY (N/C) LH LIGHT SWITCH (DOOR OPEN) PURPLE (N/O) PURPLE (COM) PIN 5 PIN 8 YEL/PNK FREEZER DOOR SWITCH (DOOR OPEN) INLINE CONNECTOR ABBREVIATION KEY ABBR. EXPLANATION AT1 9 PIN CONNECTION AT AIR TOWER 9 PIN CONNECTION IN FRESH IM1 FOOD ICEMAKER COMPARTMENT 6 PIN CONNECTION IN FRESH IM2 FOOD ICEMAKER COMPARTMENT 6 PIN CONNECTION AT THE LEFT LH1 DOOR UPPER HINGE 5 PIN CONNECTION AT THE LEFT LH2 DOOR UPPER HINGE 9 PIN CONNECTION IN THE MAIN MB1 BOARD HOUSING BEHIND THE TOE GRILLE 4 PIN CONNECTION IN THE MAIN MB2 BOARD HOUSING BEHIND THE TOE GRILLE 9 PIN CONNECTION IN THE MC1 MACHINE COMPARTMENT TO THE LEFT OF THE COMPRESSOR 8 PIN CONNECTION IN THE MC2 MACHINE COMPARTMENT TO THE LEFT OF THE COMPRESSOR 9 PIN CONNECTION AT THE RIGHT RH1 DOOR UPPER HINGE 5 PIN CONNECTION AT THE RIGHT RH2 DOOR UPPER HINGE 2 PIN CONNECTION AT THE RIGHT RH3 DOOR UPPER HINGE 1 2 4 6 RH LIGHT SWITCH (DOOR OPEN) YEL/GRY YEL/GRY YEL/PNK BLK/ORN BLK MB1 PIN 4 PIN 5 YEL/PNK YEL/PNK NEUTRAL 5 6 J5 3 4 11 J5 7 12 J5 8 RL1 +12V DC 1 5 J1 4 J2 BLK GND BLK PIN 3 LT. BLU PIN 2 BRN BLK/ORN YEL/PNK PIN 4 FREEZER EVAPORATOR HEATER MB2 +12V DC +12V DC 1 J8 2 1 2 4 6 YEL/BLK (COM) YEL/GRY (N/C) PUR/BLK (N/O) PURPLE (COM) RH1 11 12 LINE +12V DC FREEZER ICEMAKER WATER VALVE PIN 1 3 OUT1A 1 OUT2A RL6 OUT2B J3 2 J2 2 BROWN/BLUE BLU/WHT BROWN PIN 7 AUGER MOTOR BLU/WHT PIN 3 PIN 2 MC1 RL3 J3 1 PIN 9 DEFROST BIMETAL CUBE/CRUSH SOLENOID AUGER MOTOR PURPLE PIN 7 PUR/BLK BEHIND FRONT LEFT ROLLER ICEMAKER EVAPORATOR HEATER PIN 1 PIN 8 +5V DC BOARD-MOUNTED AMBIENT THERMISTOR GRN/YEL PIN 5 IM1 RL2 YEL/BLU 2 COIL COVER GROUND CABINET WRAPPER OUT1B FREEZER DOOR SWITCH (DOOR OPEN) 4 FREEZER ICE MAKER (SEE FZ ICE MAKER DIAGRAM) ERF2500++ISO REFRIGERATOR CONTROL YEL/PNK THERMAL CUT-OUT PIN 4 RH1 +5V DC +5V DC SPLICE PIN 4 IM1 LT. BLU PURPLE (COM) PURPLE (N/O) 6 4 2 1 1 YEL/BLU 6 4 2 1 EVAPORATOR FAN (DC) YEL/WHT PIN 2 4 3 4 5 6 7 J4 8 9 BOARD VIEW LH LIGHT SWITCH (DOOR OPEN) YEL/GRY (N/C) YEL/BLK (COM) RH LIGHT SWITCH (DOOR OPEN) PURPLE (COM) PUR/BLK (N/O) YEL/GRY (N/C) YEL/BLK (COM) J9 J10 2 4 J1 RH1 RH3 LH1 LH2 FRONT INSIDE VIEW IM1 RL2 1 RL3 1 RL6 9 LH2 & RH2 LH1 4 3 9 1 1 BACK VIEW 7 1 1 7 6 MB1 3 3 6 3 9 9 3 1 7 7 1 MB2 4 8 8 4 1 5 5 1 RL8 2 2 1 1 J8 AMBIENT TEMP SENSOR 1 J4 1 1 J7 U2 RL4 RL7 J5 1 1 1 MC2 MC1 MC2 LATCH CATCH AT1 MC1 RH3 5 5 4 2 RL9 J3 3 12 1 RL5 IM2 AT1, IM1, MB1, & RH1 11 J6 J2 RH2 1 4 RL1 1 3 J11 IM2 2 4 4 2 3 6 6 3 1 3 3 1 1 4 4 1 MB2 Wire Diagram A01830901