Download SERVICE DATA SHEET 242199300
Transcript
90°F (32°C) Ambient SERVICE DATA SHEET 242199300 32 to 40% 100% FREEZER ICE MAKER - AUTOMATIC DEFROST -6° to 6°F -21° to -14°C -6° to 6°F -21° to -14°C 33° to 46°F 0.5° to 8°C 33° to 46°F 0.5° to 8°C PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0° CONTROL SETTING (2500++ CONTROL) Variable Speed Compressor Operating Time Freezer Temperature Refrigerator Temperature 65°F (18°C) Ambient System Diagnostic Mode IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION. N/A Low Side Pressure (cut-out) -2 to 2 psig -14 to 14 kPa -2 to 2 psig -14 to 14 kPa High Side Pressure 85 to 95 psig 586 to 655 kPa 120 to 135 psig 827 to 931 kPa FZ FF FZ FF -- OP Open FF Thermistor Manual Defrost d F FF UP and FF DOWN / same to deactivate OP -- Open FZ Thermistor Display / Showroom 77 77 FZ UP and FF DOWN / Power-on-Reset (POR) 60 to 70 Amps (running) 0.5 to 1.1 0.7 to 0.9 Base Voltage 115 vac (127 vac max) DEFROST SPECIFICATIONS Thermostat Cabinet Size 23’ SD, 28’ SD, 23’ CD Deactivate: Press FF UP for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity. Note: Silence alarm. Test 5 to 12 psig 34 to 83 kPa 40 to 55 Press FZ UP and FZ DOWN temperature pads for up to 10 sec. simultaneously. Press FF UP to advance through tests. • Tests marked with “*” may not be applicable to this unit and will not be displayed in System Diagnostic Mode. • Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through. • View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests. • Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests. BOTTOM FREEZER - R134a Low Side Pressure (cut-in) Wattage Activate: Heater Error Codes Display -- SH SH -- Cutout Watts Ohms 25°F (-4°C) 47°F (8°C) 500 26 Display Interpretation Mode Sb Activate/Deactivate (press for up to 10 sec. simultaneously) Shorted FF Thermistor Sabbath Shorted FZ Thermistor System Diagnostic CF UI to Main Control Board communication failure; on start up SY CE UI Main Control Board communication error; after a period in operation Notes: • Always check for pin back-outs, pinched or damaged wires before replacing components. • Determine whether failure is caused by the component, main control board or wiring. Contact TID before replacing main control board. • Refer to Service Manual for additional information. SY EF Evaporator Fan Failure SY Cut-in Special Modes Sb FZ UP and FZ DOWN / FF UP to deactivate Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time. -- All LED lights on UI illuminated -- Second Screen -- All segments on UI temperature displays illuminated -- Third Screen -- Blank UI display, no lights illuminated, no shadowing; “-” and “+” blinking on FF display side to show location. 28 Dispenser Paddle Press disp. paddle “on” on UI when depressed; “off” when released 1* Standard Compressor Press power on-off Compressor running when “on”; stopped when “off” 2 Defrost Heater Press power on-off Defrost limit switch must be closed; verify “CL” in test 26. Feel for heat from defrost heater when “on”. If “OP” in test 26, heater will not activate. 3 FF Light Press power on-off With FF door open, FF lights on when “on”; off when “off” 8 Water Valve (Dispenser) Press power on-off FF door must be closed. Be prepared to collect water at dispenser. Water dispenses when “on”; stops when “off” 9 FZ Light Press power on-off With FZ door open, FZ lights on when “on”, off when “off” 10 Auger Motor Press power on-off FF door must be closed. Motor running when “on”; motor stopped when “off” 11 Cube/Crush Solenoid Press power on-off FF door must be closed. Do not leave solenoid in activated state. Solenoid activated when “on”; deactivated when “off” 41* Perfect Temp Drawer (PTD) Press power on-off PTD UI illuminated when “on”, off when “off” 12* VCC Condenser Fan Press power on-off Fan running when “on”; stopped when “off” 38* VCC Compressor Press power on-off Compressor running when “on”; stopped when “off” 15 Evaporator Fan Press power on-off Fan running for minimum of 10 sec. when “LO” or “HI”; stopped when “off”. Feedback failure if fan starts but runs less than 10 sec. Listen for speed change from “LO” to “HI”. 22 Damper Press power on-off With inspection mirror, observe damper open when “OP”; closed when “CL” 23 FF Door Open/close FF door “CL” on UI when door closed; “OP” when open 24 FZ Door Open/close FZ door “CL” on UI when door closed; “OP” when open 26 Defrost Limit Switch Activates automatically “CL” on UI when closed; “OP” when open 36 Ice Chute Door Depress ice chute door or press power on-off “OP” on UI when manually opened; “CL” when closed. Or, using “power onoff”, “OP” on UI when solenoid activated, “CL” when deactivated 29 FF Thermistor Midlevel Activates automatically UI shows temperature sensed by FF thermistor; pass if within 10°F of temperature measured with gauge at mid-level FF thermistor location. “OP-” if open; “SH-” if short 30 FZ Thermistor Activates automatically UI shows temperature sensed by FZ thermistor; pass if within 10°F of temperature measured with gage at FZ thermistor location. “OP” if open; “SH” if short 33 Ambient Thermistor @ Main Board Activates automatically UI shows temperature sensed at main board; pass if within +20°F/-10°F of temperature measured with gauge at main board location. “OP” if open; “SH” if short 35* FF Thermistor Upper-Level Activates automatically UI shows temperature sensed by upper level FF thermistor; pass if within 10°F of temperature measured with gauge at upper-level FF thermistor location. “OP¯” if open; “SH¯” if short 34* Ambient Thermistor @ UI Activates automatically UI shows temperature sensed at UI; pass if within +20°F/-10°F of temperature measured with gauge at UI location. “OP” if open; “SH” if short 0- Firmware Parameters Press power on-off Displays digit sequence; record 2- Main Board Firmware Press power on-off Displays digit sequence; record 4- UI Firmware Press power on-off Displays digit sequence; record CONDENSER FAN MOTOR 3.1 (Energy Star, some models) RPM 1100 CW Opposite Shaft Amps 0.03 Running FREEZER ICE MAKER SPECIFICATIONS LINE Electrical 115 vac (127 vac max) Thermostat Opens at 48°F (9°C), Closes at 15°F (-9°C) Heater Voltage 115 vac ICE MAKER 1 Green / Yellow Ground Yellow BLK RED HOLD SWITCH ICE MAKER Connects to: RED NC C LT. BLUE NO NO BLU BLK Water Valve C MOLD HEATER 3 Black Line 4 Light Blue Neutral P-4 THERMOSTAT 165 WATTS NO GRN / YEL P-1 C MOLD MOUNTING PLATE ICE MAKER NC SHUTOFF SWITCH NC YELLOW WATER FILL SWITCH WATER VALVE Wire Color MOTOR LT. BLUE THERMAL CUT-OUT FREEZER ICE MAKER CONNECTOR PLUG CONNECTIONS Wire Number ICE MAKER BRN BLK P-3 2 NEUTRAL POWER RED Watts P-2 FREEZER ICE MAKER INFORMATION (Where Applicable) All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner. Water Fill Volume: The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked. IMPORTANT SAFETY NOTE Water Fill Adjustment Motor Gear TU R N CAUTION Test Cycling: Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. Passing result First Screen FZ DOWN and FF UP / same to deactivate No FF or FZ display, all UI LEDs on. To activate test: -- Mounting Plate Screws The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance. IMPORTANT Mounting Plate Screw Timing Gear If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured. CAB-DOOR INLINES LEFT DOOR GROUND LEFT DOOR HINGE GROUND 5 5 1 BLK/ORN Z1-2 1 7 7 1 9 9 3 LED LIGHTS LEFT DOOR INLINE FRESH FOOD THERMISTOR 3 GRY/BLK AIR TOWER INLINE RIGHT DOOR INLINES 3 GRY/BLK 4 BRN/YEL RED/YEL 5 6 4 3 WHT/YEL B2 BLK/YEL A2 2 BRN/YEL 1 RED/YEL B1 A1 LED POWER SUPPLY DAMPER MOTOR 7 8 BLU 2 3 4 5 7 8 9 10 12 13 14 15 RIBBED 7 8 9 1 2 3 LT. BLU/BLK 4 5 6 CATCH LT. BLU 3 6 2 5 1 4 BLK BLK/WHT 12V+ BLK RED/BLK 12V- RED BLU YEL 1 4 1 BRN/YEL RED/WHT WHT/YEL RED/YEL 9 J4B J2 RED J1 1 1 J9A 1 RED 2 WHT 3 BLK 12 YEL/BLK 6 YEL/PNK 11 5 10 4 9 3 8 RED 2 7 1 BRN 1 LT. BLU BLK 3 2 GRN/YEL 4 BLK/RED 2 WHT/BLU 1 YEL LT. BLU/BLK GRN/YEL LT. BLU YEL/BLK RED/BLK BLK/PNK GREEN I/M WATER VALVE YEL TYPICAL LED CONNECTOR Z4-1 1 1 2 BLK/WHT Z1-1 ZONE 4 FF DOORS AND BACK OF FREEZER Z4-3 LED - 1 + 2 WHT/GRN 1 BLK/BRN MACHINE COMPARTMENT INLINE AT CONTROL BOARD Z4-2 + - 1 4 2 5 3 6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 BLK RED - LED BLK/YEL 12 + BLK/ORN BLK/BRN MAIN BOARD 16 8 YEL/RED 15 7 14 LT. BLU 6 BLK/PNK 13 5 12 4 LT.BLU/BLK 11 YEL/RED 3 BLK/ORN 10 YEL 2 RED/BLK 9 YEL 1 BLK/WHT WHT/RED 1 BLK/ORN 2 J3 + Z1-4 + J4A LED LED - 2 WHT/BRN 1 BLK/PUR DAMPER MOTOR LED LIGHTS M OUT 1A J4B-6 OUT 2A J4B-1 OUT 1B J4B-2 OUT 2B J4B-3 NTC - FF J4A-3 J4A-9 NTC - FZR J4A-5 J4A-11 REFRIGERATOR CONTROL J3 J2 J4A J4B 8 1 4 9 2 5 1 2 6 3 3 1 5 11 8 16 7 15 4 2 4 10 6 14 10 3 3 9 5 13 11 4 2 8 4 12 12 5 1 7 3 11 13 6 2 10 14 7 6 12 1 9 NEUTRAL DEFROST HEATER J2-1 FG VCC(+12) DC EVAPORATOR FAN M COM VS VCC COMPRESSOR M If test 38 fails, diagnose as follows: FREEZER LIGHTS LINE J1-1 J3-9 NEUTRAL J1-3 LINE NEUTRAL LED POWER BOARD J1-4 J1-1 G5LE RELAY J4A-7 J4B-5 J4A-13 J9A-1 J9A-2 J9A-3 VEE (+12 ) COMM GROUND J8-5 J8-6 J8-7 J8-8 ASSY_OU T ASSY__IN +5 V GROUND JF-1 JF-2 JF-3 JF-4 +5V RESET_ FLASH BKGD / MSJ GROUND J4A-14 J3-2 J3-1 CONDENSER FAN Variable Capacity Compressor (VCC) Diagnostics (select models) FZR DOOR SW. SENSE J2-6 DEFROST THERM. D REFRIGERATOR LIGHT S J1-3 J2-12 NTC - AMBIENT J1 REFRIGERATOR DOOR OPENING IS DETERMINE BY MAGNETIC SWITCH ON USER INTERFACE J3-8 J3-11 LINE UI A 9 BRN 4 12 11 10 9 8 7 6 5 4 3 2 1 COND. FAN ISOLATED 12 Z1-2 - FRZR FAN (DC) Z1-3 VARIABLE SPEED COMPRESSOR/ INV. LED 1 8 2 GRY/BLK 9 GRY/BLK 3 10 4 GRY/WHT 11 5 GRY/WHT 12 6 BRN/WHT 13 DK.BLU/WHT 7 YEL/WHT 14 FREEZER INLINE AT CONTROL BOARD FREEZER DOOR SWITCH (N) WHITE ZONE 1 SIDE AND TOP LEDS WHT/RED 1 BLK/ORN 2 SPLICE 1 GRY/WHT (L) PUR 12 VDC (120V AC REF.) 3 FREEZER THERMISTOR 1 2 GRN/YEL 2 GRY/WHT LATCH CATCH FRESH FOOD COMPARTMENT INLINE AT CONTROL BOARD 4 BRN BLK/ORN GRY/WHT GRY/WHT YEL YEL/PNK BLU/WHT YEL/WHT LT. BLU YEL/RED BRN/WHT RED/WHT J1-1 LED LIGHTS 5 9 8 7 6 3 5 2 4 1 COMPRESSOR GROUND GROUND ATTACHED TO CABINET BEHIND LEFT ROLLER COIL COVER GROUND J1-3 NEUTRAL LT. BLU 6 11 J1-4 J1 DEFROST THERM. ICE MAKER (SEE ICE MAKER DIAGRAM) WHT/BRN J2-4 RIGHT DOOR 1 DEFROST HEATER CATCH COMPARTMENT - BLK/ORN BLK/BRN 5 WHT/BLU 2 1 10 4 7 8 BLK/BLU BLK/RED 9 3 J2-3 FREEZER SWITCH (120V AC) FRESH FOOD SWITCH (120V AC) WHT/GRN - 13 Z4-3 WHT/RED - 8 2 1 2 3 WHT/RED BLK/ORN 12 + Z4-2 LATCH 15 7 1 4 5 FREEZER 14 6 BLK 15 14 GRY/BLK 13 GRY/BLK 12 RED/YEL 11 WHT 10 9 WHT/YEL 8 7 BRN/YEL 6 BLK/YEL RED 5 4 3 LT. BLU 2 YEL/BLK 1 YEL/RED 11 9 8 7 FRESH FOOD INLINE IN MACHINE COMPARTMENT RIGHT DOOR GROUND 3 8 6 RIGHT DOOR HINGE GROUND FLIP MULLION HEATER J2-8 Z4-1 1 2 3 4 1 2 LT. BLU LT. BLU/BLK LT. BLU 3 J2 NEUTRAL GROUND LINE NON-RIBBED 1 2 LT. BLU/BLK GRN/YEL LT. BLU/WHT 7 4 5 9 LATCH MULLION GROUND 2 LED 2 BLK/YEL 2 - + BLK/BRN LED POWER BOARD (J2) 1 1 6 2 1 1 GRY/BLK WHT/YEL 5 BLK/PUR BLK/BLU LED IN RIGHT FF DOOR BLK/ORN GRY/BLK Z1-4 LED POWER PCBA J2 LED 5 4 + RED J2-7 5 4 3 2 1 1 1 BLK WHT 3 2 1 WHT/RED 3 J2 + Z1-3 1 2 LEFT DOOR LED IN LEFT FF DOOR YEL/BLK YEL/RED 1 USER INTERFACE BOARD Z1-1 LATCH CATCH J2-1 ERF2500++ → Check at the connector from the power cord harness into the inverter board, located in the machine compartment. (PUR and WHT wires) → yes no • Check voltage supply. Check and repair power cord harness wiring and connections. → yes Is Inverter Board receiving 10-15 VAC and 1-5 VDC from Main Control Board? Is Inverter Board receiving 115 VAC from power supply? • Check at Inverter Board on Compressor (BLK and RED wires) Remove inverter box from the compressor and check resistance across compressor winding pairs as shown. Is resistance across all winding pairs equal? no Check at Main Control Board (BLK/WHT and RED/BLK wires) Is Main Control Board sending 10-15 VAC and 1-5 VDC to Inverter Board? yes Identify and repair damaged wires or poor connections between Main Control Board and Inverter Board. yes Check connections from Inverter Board to Compressor no IM WATER SENS Are connections from Inverter Board to Compressor intact? no Replace Compressor and Inverter Board. → → E J3-9 J3-10 no LINE Identify and repair damaged wires or poor connections between Inverter Board and Compressor. J3-6 J3-4 yes ICE MAKER FILL VALVE NEUTRAL FZ ICE MAKER OUTPUT LINE (PTD) MULLION HEATER Replace Main Control Board. VCC Resistance Check J3-3 Replace Inverter Board Check resistance between terminals 1 and 2, 2 and 3, 3 and 1. If all resistances are equal, compressor is operative. Wire Diagram 242199201 FREEZER ICE MAKER ERF2500++ ERROR CODES: FREEZER DISPLAY: "OP" OR "2" - FREEZER THERMISTOR "OPEN" "SH" OR "3" - FREEZER THERMISTOR "SHORTED FRESH FOOD DISPLAY: "OP" OR "2" - FRESH FOOD THERMISTOR "OPEN "SH" OR "3" - FRESH FOOD THERMISTOR "SHORTED" BOTH DISPLAYS: "SY CE" - COMMUNICATION ERROR "SY CF" - COMMUNICATION LOST ERROR "SY EF" - EVAPORATOR FAN ERROR " "