Download AR-M207 AR-M165 AR-M162

Transcript
[13]ELECTRICALSECTION.fm 4 ページ 2004年11月12日 金曜日 午後2時21分
(4) Reset circuit
This circuit detects ON/OFF of power to control start/stop of each circuit. The 3.3V voltage of the main PWB is detected by the reset IC to generate the
reset signal.
When the power voltage reaches the specified level, the circuit operations are started. Before the power voltage falls below the specified level, the
circuit operations are stopped to prevent against malfunctions.
CPU
(ASIC Reset)
Reset_OUT
2
PF6
ASIC
3
1
IC5A
/RES
VCC3
VCC3
R18
11kF
R19
10kJ
IC4
1
2
3
4
R21
10kF
NC
IN
NC
GND
8
7
6
5
NC
VCC
OUT
Cd
M51957BFP
C23
0.1u
C24
22000p
(5) Heater lamp control circuit
a. Outline
The heater lamp control circuit detects the heat roller surface temperature and converts in into a voltage level. The converted voltage is inputted to the
CPU analog input pin.
The CPU converts the inputted analog voltage into a digital signal level and compares it with the set value of the simulation to control on/off the heater
lamp according to the level, maintaining the heat roller surface temperature at a constant level.
VCC3
R88
7.5kF
T376
3
+
2
-
1
D2
R89
1kJ
4
R98
2.7kF
T380
1
MA700
R97
10kF
IC23A
FTH
1
R87
1MF
VCC3
8
R86
1kF
24V
KIA393F-EL
24V
VCC3
8
+
2
-
IC27A
T403
R109
300J
T404
10kJ
R110
100J
C129
24V
4
DSCLK#
1SS355
RTH
KIA358F-EL
C128
22000p
Q5
DTC114EKA
IN
1
1
3
1
RTH_IN
D1
R288
OUT
24V
INT5V
5VEN
GND
0.1u/50V
1
3
2
D3
DAN202U or KDS121
C127
T371
0.1u
1
1
C130
0.1u/50V
IC22
R114
10kJ
8
T416
1
5
6
+
IC23B
1B
2B
3B
4B
5B
6B
7B
G
1C
2C
3C
4C
5C
6C
7C
NC
16
15
14
13
12
11
10
9
T372
PMCLK_A
R243
1
*0J
T385
KID65503F
7
T374
2
1
1
2
3
4
5
6
7
8
(/AUD_PNC)
(/AUD_COPY)
(/AUD_CA)
3
1
R113
1.2kF
T373
T375
T379
1
PMCLK
DSCLK
HL
FTH
AUD_PNC
AUD_COPY
AUD_CA
5V
1
24V
1
VCC3
R93
240J
R94
240J
THOPEN
KIA393F-EL
4
R115
10kF
C136
HLOUT
22000p
VCC3
D5
24V
KDS226
1
3
5
TCCNT
6
+
IC27B
-
C137
T421
R117
7
(TCCNT)
1
8
2
300J
4
KIA358F-EL
N.M.
The lower the heat roller surface temperature is, the greater the thermistor resistance is, and vise versa.
Therefore, the lower the heat roller surface temperature is, the higher the thermistor terminal voltage is, and vise versa. The thermistor terminal voltage
is inputted to the CPU analog port.
The CPU controls ON/OFF of the heater lamp by this input voltage level.
AR-M207 M165 M162 ELECTRICAL SECTION 13-4