Download FS-1800/N FS
Transcript
(1) A0 Zero cross signal error Meaning Suggested causes The ZCROSS signal • Defective power supply unit. does not reach the engine board within • Defective CPU U201 on the engine board. 3 seconds after power on. Corrective action Replace power supply unit. See page 5-22. Replace engine board. See page 5-22. (2) A2 Abnomal high temperature error Meaning CPU U201 detected that the HTEMP* signal (Abnormal temperature of more than approximately 220 °C) is low for more than 3 seconds. Suggested causes Corrective action • Defective CPU U201 or comparator U205 Follow the flow chart on the engine board. below. • Defective engine board (KP-864). • Defective thermistor. • Defective photo coupler on the power supply unit for the heater lamp. Call service personA2:0123456 Turn power switch off. CAUTION: Fuser unit is fed directly by AC power from primary circuit on power supply board. Be careful with electricshock. Remove and check harness (S02415) between fuser board (KP-756) and power supply unit. No OK? Yes Replace harness (S02415) between fuser board (KP756) and power supply unit. Turn power switch on. Replace fuser unit. See page 5-29. Measure voltage at pin #6 (THERM) of YC831 on fuser board (KP-756). More than 3 V DC over 3 seconds? NOTE: If the problem is not solved by this flow chart replace, the following items: No Replace engine board (KP-864). See page 5-22. Yes FS-1800/1800N | FS-3800/3800N 6-12 Engine board (KP-864) Power supply unit Fuser unit