Troubleshooting (OP: Schedule Timer) 7.4 PACD011001C2 Improper Combination of Optional Controllers for Centralised Control Remote Controller Display Supposed Causes MA „ Improper combination of optional controllers for centralised control „ More than one master controller is connected. „ Defect of PC board of optional controllers for centralised control Troubleshooting Caution Be sure to turn off power switch before connect or disconnect connector, or parts damage may be occurred. Is the schedule timer's individual/combined connector connected? YES Are any other optional controllers for centralised control connected? NO NO Other optional controllers for centralised control cannot be used YES in combination when the schedule timer's individual / combined connector is connected. Disconnect the connector, connect the connector for setting master control to one of the optional controllers, and reset the power supply for all optional controllers for centralised control simultaneously. Reset the power supply for the schedule timer. Is the "BMS interface adaptor for individual and unified control, for unified group" connected? YES NO Is a data station connected YES NO Is a parallel interface connected? YES NO Are there two or more optional controllers for centralised control connected with the connector for setting master control? Cannot be used in combination with a "BMS interface adaptor for individual and unified control, for unified group". Remove them and reset the power supply for all optional controllers for centralised control simultaneously. Schedule timer and data station cannot be used in combination. Disconnect either the schedule timer or data station and reset the power supply for all optional controllers for centralised control simultaneously. Schedule timer and parallel interface cannot be used in combination. Disconnect either the schedule timer or parallel interface and reset the power supply for all optional controllers for centralised control simultaneously. YES Arrange so that the connector for setting master control is connected to one controller for centralised control and reset the power supply for all optional controllers for centralised control simultaneously. If the malfunction is still not cleared: Disconnect the connector for setting master control from the master controller, connect to another optional controller for centralised control and simultaneously reset all optional controllers for centralized control again. The controller connected by the connector for setting master control when the malfunction is cleared is defective and must be replaced. NO Reset the power supply for all optional controllers for centralised control simultaneously. (VF077) 398 Troubleshooting Urban Multi “MX1R, ME1R Series” Using R-407C
Related documents
Service Manual - daikin tech.co. uk
Service Manual
Manuale di servizio - H-Tec
Service Manual
SM_Si-95_Inverter K Series
Service Manual - Daikintech.co.uk
Descargar
Manuale - H-Tec
Service Manual - Daikintech.co.uk
Manual de instalación y mantenimiento de tuberías de refrigerante
VRV-IIIC ColdRegion SiBE31-801C tcm135
Manuale di servizio - H-Tec