Download 25WG3
Transcript
VCO ADJUSTMENT (I2C BUS CONTROL) AGC ADJUSTMENT (I2C BUS CONTROL) 1 2 7 Figure 1 BIAS BOX : ABOUT 4.5V OSCILLOSCOPE P201 TV SET 2 1 9. Call "AGC" in SERVICE mode. 10. Increase or decrease "AGC" by using Volume so that obtain the highest Voltage. 11. Press Volume slowly in the opposite direction until the voltage drops 0.1V ~ 0.3V lower than the highest level. 12. Change the antenna input signal to 63 ~ 67dBµV, and make sure there is no noise. 13. Turn up the input signal to 90 ~ 95 dBµV to be sure that there is no cross modulation beat. - + - + 7. Receive E-12CH (PAL COLOR BAR) signal. Signal strength : 57 ± 1 dB ( 75ohm open) 8. Connect the oscilloscope to P201 (Tuner’s AGC Terminal) as shown in Figure 1. 1. Receive E-10CH (210.25MHz) "PAL Signal Strength: 60 ~ 70 dB COLOUR BAR" signal. 2. Call "AUTO VCO" in SERVICE mode. If the Channel frequency displays on screen is 210.20MHz, skip (3), (4) & (5) steps. 3. Press FUNCTION button to call "DIRECT FREQ IN". 4. Push "2", "1", "0", "2", "0". 5. Then Press FUNCTION again. 6. Press Volume UP to run "AUTO VCO". Once finishing, "OK" message display on screen. NO ADJUSTMENT POINT ADJUSTMENT CONDITION/PROCEDURE WAVEFORM OR OTHERS VCO, AND AGC ADJUSTMENT SERVICE ADJUSTMENT NOISE MUTE CHECKING SP SUB VOLUME (I2C BUS CONTROL) 2 3 RF SUB VOLUME (I2C BUS CONTROL) 1 10. Receive the 400Hz modulated signal. 11. Turn up the volume control to Maximum and make sure the sound is heard from the speakers. Then put the unit in the no-signal state. 12. Be sure that the sound mute is effective. 13. Finally turn down the volume control to minimum. 5. Receive "COLOUR BAR" signal. *Note : Terminated 8 ohm Audio signal: 400Hz, 100%modulation. to get 7.75 ± (50kHz dev.) 0.1Vrms. 6. Connect Dummy load* to P3304. (L Channel) 7. Connect VTVM’s probe to the P3304. (1 R, 2 GND, 3 GND, 4 L, 5 NIL, 6 NIL 7 NIL 8 NIL) 8. Call the "SP SUB VOL" in the SERVICE mode. 9. Increase or decrease "SP SUB VOL" by using Volume UP/DOWN key, so that the VTVM should read the value*. 1. Receive "PAL COLOUR BAR" signal. Audio signal: 400 Hz, 100% modulated (50kHz dev.) 2. Connect the Oscilloscope to the Audio Out (L or R) terminal. (Terminate with 10k ohm impendence). 3. Call the "RF SUB VOL" in SERVICE mode. 4. Increase or decrease "RF SUB VOL" by using Volume UP/DOWN key, so that the 400Hz sine wave be 1.76Vp-p. Tolerence: 1.76 Vp-p ± 0.10 Vp-p. NO ADJUSTMENT POINT ADJUSTMENT CONDITION/PROCEDURE WAVEFORM OR OTHERS SOUND ADJUSTMENT 25WG3