Download Room Air Conditioner SVC MANUAL(Exploded View) MODEL : LS
Transcript
http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : LS-H0764JM3(S07LHP N41) CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. 1. Specification Models Cooling Capacity (Min~Rating~Max) Heating Capacity (Min~Rating~Max) Power Input Running Current Starting Current EER COP Power Supply Power Factor Air Flow Rate Cooling/Heating Cooling/Heating Cooling/Heating Indoor,Max Outdoor,Max Moisture Removal Sound Level Indoor,H/M/L Outdoor,Max Refrigerant & Charge(at 7.5m) Compressor Type Model Motor Type Oil Type Oil Charge O.L.P Name Fan(Indoor) Type Motor Output Fan(outdoor) Type Motor Type Motor Output Circuit Breaker* Power Supply Cable Power and Transmission Cable Piping Liquid Side Connections Gas Side Drain Hose O.D , I.D Dimension Indoor(W*H*D) Outdoor(W*H*D) Net Weight Tool Code(Chassis) Functions Network Functions LS-H0764JM3 kW Btu/h kW Btu/h W A A W/W Btu/h.W W/W Ø / V / Hz % mm2/min(cfm) mm2/min(cfm) l/h dB(A)+3 dB(A)+3 g(oz) cc W W A No.*mm2 No.*mm2+No.*mm2 mm(in) mm(in) mm(in) mm inch mm inch kg(lbs) kg(lbs) Indoor Outdoor Indoor + Outdoor Temperature Control Plasma Filter Prefilter(washable/anti-fungus) Auto Clean CHAOS Wind(Auto Wind) Steps, Fan/Cool/Heat Airflow Direction Control(up&down) Airflow Direction Control(left&right) Remocon Type Setting Temperature Cooling Range Heating Auto Operation (Micom Control) Auto Changeover (Micom Control) Self Diagnosis Timer Sleep Operation Soft Dry Operation Restart Delay(minute) Deice Control(Defrost) Hot Start Jet Cool Low Ambient Operation Special Function Dry Contact Network Solution(LGAP) PI485 Note: O : Applied, - : No relation * For circuit breaker rating, please conform to local standards wherever necessary. 2 Room Air Conditioner 2.3 7,850 2.5 8,530 940/840 4.2/3.7 2.45 8.35 2.98 1/220~240/50 97.3 5.8(205) 23(812) 1 32/29/26 47 R22, 700(24.7) Rotary(Non Tropical) PH165X1C PSC SUNISO 4GSD/ATMOS NM56EP 400 B160-135-241E Cross Flow Fan 25 Propeller AC Induction 55 15 3*1.0 3*1.0 6.35(1/4) 9.52(3/8) 21.5,16(0.85,0.63) 840*270*163 33.07*10.63*6.42 717*498*229 28.23*19.61*9.02 7.3(16.09) 25.8(56.88) S4 + UA3 Thermistor Neo O O O 3/4/3 Auto Auto Wireless LCD 18 ~ 30 16 ~ 30 O O 24h, On/Off O O 3 O O O ❈ Some of functions are slightly different depending upon models. ❈ The specification may be subject to change without notic for purpose of improvement. 2. Piping Diagrams Indoor Unit Outdoor Unit Liquid Side Capillary Tube 2-Way Valve Th2 Th1 Heat Exchanger (Evaporator) Heat Exchanger (Condenser) Gas Side Reversing Valve 3-Way Valve Accumulator LOC. Description Th1 Thermistor for indoor air temperature Th2 Thermistor for evaporating temperature Compressor Cooling Heating PCB Connector CN-TH1 Service Manual 3 3. Wiring Diagrams TRIAC BL(WH/Ribbed) OR BR(BK/Plained) GN/YL MAIN PWB ASM. MOTOR BK CN-MOTOR BR YL SH-CAPA CN-N1 1(L) 2(N) 1(L) 2(N) 4 3 RY-COMP GN/YL CN-N2 FUSE 250V T2A 3 3 RY-4WAY BR BL GN/YL BK RD 4 4 TERMINAL BLOCK CN-4WAY RY-FAN TO OUTDOOR UNIT CN-L/R CN-N2 CN-U/D CN-DISP1 CN-DISP2 CN-12V CN-HVB POWER CONDUCTIVE ENCLOSURE MOTOR ONLY CN-L/R CN-U/D CN-OPTION CN-TH1 Indoor Unit THERMISTOR OPTION PWB ASM. STEP MOTOR STEP MOTOR H.V. ASM. BK BK CN-HVB RD AIR BK CLEAN (PLASMA) BK BK S/W1 DISPLAY PWB ASM. P/No : 3854A20427B CN-DISP2 CN-12V CN-TH1 CN-N1 CN-DISP1 CN-MOTOR CN-OPTION 4 Room Air Conditioner Outdoor Unit Service Manual 5 4. Exploded View Indoor Unit 135316 152302-1 152302-2 135313 131410 733010 342800 159830 359011 135311 354210 147581 352115 35211B 352116 268711-1 346810 135516 567480-2 352150 146811 267110 249951 268711-3 Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request. Please check the correct parts in View RPL(Replacement Part List) on GCSC. (GCSC Website http://biz.Lgservice.com,) 6 Room Air Conditioner Outdoor Unit 237202 437210 435301 137213 435300 237204 435511 554031 349600 546810 552113 559010 554160 447910 552202 649950 550140 561410 552203-2 552116 430410 552203-1 Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request. Please check the correct parts in View RPL(Replacement Part List) on GCSC. (GCSC Website http://biz.Lgservice.com,) Service Manual 7 P/NO : MFL37062903 DECEMBER, 2006