Download MAINTENANCE INTERVALS - Safety
Transcript
90 Maintenance Section Battery - Recycle i00637582 Battery - Recycle i01033528 Bucket Lower Pivot Pin Lubricate SMCS Code: 1401-561 Always recycle a battery. Never discard a battery. SMCS Code: 6108-086-PN Always return used batteries to one of the following locations: • A battery supplier • An authorized battery collection facility • Recycling facility i00637583 Battery, Battery Cable or Battery Disconnect Switch Replace SMCS Code: 1401-510; 1402-510; 1411-510 1. Turn the engine start switch key to the OFF position. Turn all of the switches to the OFF position. 2. Turn the battery disconnect switch to the OFF position. Remove the key. 3. Disconnect the battery cable at the battery disconnect switch. The battery disconnect switch is connected to the machine frame. Illustration 204 g00289467 Lubricate two fittings. There is one fitting on each side of the bucket. i01027107 Bucket Teeth and Cutting Edges - Inspect/Replace SMCS Code: 6801-040; 6801-510; 6822-040; 6822-510 4. Disconnect the negative battery cable at the battery. Personal injury or death can result from bucket falling. 5. Make necessary repairs or replace the battery. Block the bucket before changing bucket tips. 6. Connect the negative battery cable at the battery. 7. Connect the battery cable at the battery disconnect switch. 8. Install the key and turn the battery disconnect switch to the ON position. 1. Raise the bucket and block up the bucket. Only block up the bucket to a sufficient height for removing the bucket tips. 2. Shut off the engine.