Download T-D2-IN&OS_Service M..

Transcript
CONFIDENTIAL
T-D2-IN / T-D2-OS Service Manual
Ver. 1.00
10-11. Thermistors
#407 (Inlet)
Unit Part #
#408 (Mixing)
EKK38 (Inlet)
Takagi Part #
#411 (Output)
EKK1A (Mixing)
E1 (Mixing)
Checkpoint
EKK2T (Output)
E2 (Output)
E3 (Inlet)
Function
Measures cold/hot water temperatures in the water heater.
Failure events
Unable to properly measure water temperatures within the water heater.
Effects on the water If the thermistors fail open or short, error code appears before starting operation.
heater if thermistor If resistance values are just off, The water heater will have temperature fluctuations
fails
in hot water.
Error codes when
311 (Output)
321 (Inlet)
331 (Mixing)
thermistors fails
1. Visual inspection: connection/breakage of wires and/or debris on thermistor.
Diagnostic
2. Check voltages and resistance; proper range of values shown below.
68˚F (20°C) 9.0 to 13 kΩ
Inlet Black(42)-Black
Color/Number
of
wires
122˚F (50°C) 3.3 to 4.4 kΩ
Output Black(12)-Black
176˚F (80°C) 1.4 to 1.8 kΩ
Mixing Black(113)-Black
(see table below for more resistance values)
Black
(Inlet thermistor) 42
Blue
(Mixing thermistor) 113
Black
Insulating
(Output thermistor) 12
Resistance values of thermistors as a function of temperature
25.00
Resisitance / kΩ
20.00
15.00
10.00
5.00
0.00
20
40
60
80
100
120
140
Temperature / ºF
27
160
180
200
220