Download 42re automatic transmission
Transcript
45RFE AUTOMATIC TRANSMISSION WJ 21 - 205 DESCRIPTION AND OPERATION (Continued) GEAR C5 C4 C3 C2 C1 Park CL OP OP CL CL Temp 1 CL OP OP CL OP Reverse OP OP OP CL OP Temp 2 OP OP CL CL OP Neutral 1 OP OP CL CL CL Neutral 2 OP CL CL CL CL Temp 3 OP CL CL CL OP Drive OP CL CL OP OP Temp 4 OP CL OP OP OP Manual 2 CL CL OP OP OP Temp 5 CL OP OP OP OP Manual 1 CL OP CL OP OP TRANSMISSION TEMPERATURE SENSOR DESCRIPTION OPERATION The solenoids receive electrical power from the Transmission Control Relay through a single wire. The TCM energizes or operates the solenoids individually by grounding the return wire of the solenoid as necessary. When a solenoid is energized, the solenoid valve shifts, and a fluid passage is opened or closed (vented or applied), depending on its default operating state. The result is an apply or release of a frictional element. The MS and UD solenoids are normally applied to allow transmission limp-in in the event of an electrical failure. The continuity of the solenoids and circuits are periodically tested. Each solenoid is turned on or off depending on its current state. An inductive spike should be detected by the TCM during this test. If no spike is detected, the circuit is tested again to verify the failure. In addition to the periodic testing, the solenoid circuits are tested if a speed ratio or pressure switch error occurs. The transmission temperature sensor is a thermistor that is integral to the Transmission Range Sensor (TRS). SOLENOID SWITCH VALVE OPERATION The Solenoid Switch Valve (SSV) is located in the valve body controls the direction of the transmission fluid when the L/R-TCC solenoid is energized. The transmission temperature sensor is used by the TCM to sense the temperature of the fluid in the sump. Since fluid temperature can affect transmission shift quality and convertor lock up, the TCM requires this information to determine which shift schedule to operate in. Calculated Temperature A failure in the temperature sensor or circuit will result in calculated temperature being substituted for actual temperature. Calculated temperature is a predicted fluid temperature which is calculated from a combination of inputs: • Battery (ambient) temperature • Engine coolant temperature • In-gear run time since start-up SOLENOIDS DESCRIPTION Solenoids are used to control the L/R, 2C, 4C, OD, and UD friction elements. The reverse clutch is controlled by line pressure and the position of the manual valve in the valve body. All the solenoids are contained within the Solenoid and Pressure Switch Assembly. The solenoid and pressure switch assembly contains one additional solenoid, Multi-Select (MS), which serves primarily to provide 2nd and 3rd gear limp-in operation. DESCRIPTION OPERATION The Solenoid Switch Valve controls line pressure from the LR-TCC solenoid. In 1st gear, the SSV will be in the downshifted position, thus directing fluid to the L/R clutch circuit. In 2nd, 3rd, and 4th, it will be in the upshifted position and directs the fluid into the torque converter clutch (TCC) circuit. When shifting into 1st gear, a special hydraulic sequence is performed to ensure SSV movement into the downshifted position. The L/R pressure switch is monitored to confirm SSV movement. If the movement is not confirmed (the L/R pressure switch does not close), 2nd gear is substituted for 1st. A DTC will be set after three unsuccessful attempts are made to get into 1st gear in one given key start. DIAGNOSIS AND TESTING EFFECTS OF INCORRECT FLUID LEVEL A low fluid level allows the pump to take in air along with the fluid. Air in the fluid will cause fluid pressures to be low and develop slower than normal. If the transmission is overfilled, the gears churn the fluid into foam. This aerates the fluid and causing the same conditions occurring with a low level. In either case, air bubbles cause fluid overheating, oxi-