45RFE AUTOMATIC TRANSMISSION
WJ
21 - 205
DESCRIPTION AND OPERATION (Continued)
GEAR
C5
C4
C3
C2
C1
Park
CL
OP
OP
CL
CL
Temp 1
CL
OP
OP
CL
OP
Reverse
OP
OP
OP
CL
OP
Temp 2
OP
OP
CL
CL
OP
Neutral 1
OP
OP
CL
CL
CL
Neutral 2
OP
CL
CL
CL
CL
Temp 3
OP
CL
CL
CL
OP
Drive
OP
CL
CL
OP
OP
Temp 4
OP
CL
OP
OP
OP
Manual 2
CL
CL
OP
OP
OP
Temp 5
CL
OP
OP
OP
OP
Manual 1
CL
OP
CL
OP
OP
TRANSMISSION TEMPERATURE SENSOR
DESCRIPTION
OPERATION
The solenoids receive electrical power from the
Transmission Control Relay through a single wire.
The TCM energizes or operates the solenoids individually by grounding the return wire of the solenoid as
necessary. When a solenoid is energized, the solenoid
valve shifts, and a fluid passage is opened or closed
(vented or applied), depending on its default operating state. The result is an apply or release of a frictional element.
The MS and UD solenoids are normally applied to
allow transmission limp-in in the event of an electrical failure.
The continuity of the solenoids and circuits are
periodically tested. Each solenoid is turned on or off
depending on its current state. An inductive spike
should be detected by the TCM during this test. If no
spike is detected, the circuit is tested again to verify
the failure. In addition to the periodic testing, the
solenoid circuits are tested if a speed ratio or pressure switch error occurs.
The transmission temperature sensor is a thermistor that is integral to the Transmission Range
Sensor (TRS).
SOLENOID SWITCH VALVE
OPERATION
The Solenoid Switch Valve (SSV) is located in the
valve body controls the direction of the transmission
fluid when the L/R-TCC solenoid is energized.
The transmission temperature sensor is used by
the TCM to sense the temperature of the fluid in the
sump. Since fluid temperature can affect transmission shift quality and convertor lock up, the TCM
requires this information to determine which shift
schedule to operate in.
Calculated Temperature
A failure in the temperature sensor or circuit will
result in calculated temperature being substituted for
actual temperature. Calculated temperature is a predicted fluid temperature which is calculated from a
combination of inputs:
• Battery (ambient) temperature
• Engine coolant temperature
• In-gear run time since start-up
SOLENOIDS
DESCRIPTION
Solenoids are used to control the L/R, 2C, 4C, OD,
and UD friction elements. The reverse clutch is controlled by line pressure and the position of the manual valve in the valve body. All the solenoids are
contained within the Solenoid and Pressure Switch
Assembly. The solenoid and pressure switch assembly
contains one additional solenoid, Multi-Select (MS),
which serves primarily to provide 2nd and 3rd gear
limp-in operation.
DESCRIPTION
OPERATION
The Solenoid Switch Valve controls line pressure
from the LR-TCC solenoid. In 1st gear, the SSV will
be in the downshifted position, thus directing fluid to
the L/R clutch circuit. In 2nd, 3rd, and 4th, it will be
in the upshifted position and directs the fluid into
the torque converter clutch (TCC) circuit.
When shifting into 1st gear, a special hydraulic
sequence is performed to ensure SSV movement into
the downshifted position. The L/R pressure switch is
monitored to confirm SSV movement. If the movement is not confirmed (the L/R pressure switch does
not close), 2nd gear is substituted for 1st. A DTC will
be set after three unsuccessful attempts are made to
get into 1st gear in one given key start.
DIAGNOSIS AND TESTING
EFFECTS OF INCORRECT FLUID LEVEL
A low fluid level allows the pump to take in air
along with the fluid. Air in the fluid will cause fluid
pressures to be low and develop slower than normal.
If the transmission is overfilled, the gears churn the
fluid into foam. This aerates the fluid and causing
the same conditions occurring with a low level. In
either case, air bubbles cause fluid overheating, oxi-