WARNING
■ Do not try to set up the application while you are driving. It may cause fatal injury.
■ Do not run the engine in a confined place. They contain carbon monoxide, which is fatal if inhaled.
1.Before Injection Setting
・
Check the battery voltage.
・
Check if fuel regulator and fuel pomp are working properly.
・
Replace fuel filter.
・
Check fuel and vacuum lines for any leak and damage. Replace if necessary.
・
You will have to replace the fuel pump and short circuit fuel pump register as REYTEC does not use
fuel pump control modulator (the modulator) of PS13 (RPS13). Modify the wiring to obtain power
supply. The modulator reduces noise from the pump, and it also reduces the output of the pump
even.
・
S13NA, P10, S14 and S15 do not have the modulator.
2. Fitting A/F Meter (Obtaining A/F logger output signal)
・
See previous pages “Fitting the Terminals” as a reference to obtain signal from A/F meter.
※REYTEC accepts logger input signal of 5v at maximum.
3. Connecting REYTEC
・
Make sure all connectors of REYTEC, Air-temperature sensor and Boost pressure sensor are
hooked up tight.
・
Set the cable to the diagnosis connector of the vehicle.
・
Turn ignition ON, and start the application.
21