Download caution! - Climatemaster

Transcript
THE SMART SOLUTION FOR ENERGY EFFICIENCY
Tr a n q u i l i t y ® ( T R ) S e r i e s
R e v. : 0 7 / 1 8 / 1 3
Model Nomenclature - General Overview
1
2
3
4 5 6
7
8
9
10
11
12
13
14
15
TR
H
036
A
G
C
3
0
C
L
B
S
S = STANDARD
MODEL TYPE
®
TR = TRANQUILITY HIGH EFFICIENCY 410A
SUPPLY AIR OPTIONS
CONFIGURATION
B = BACK DISCHARGE, HORIZONTAL ONLY
Y = BACK DISCHARGE, HIGH STATIC
HORIZONTAL 015-060 COMMERCIAL ONLY
T = TOP DISCHARGE, VERTICAL ONLY
V = TOP DISCHARGE, HIGH STATIC
VERTICAL 015-060 COMMERCIAL ONLY
S = STRAIGHT DISCHARGE, HORIZONTAL ONLY
Z = STRAIGHT DISCHARGE, HIGH STATIC
HORIZONTAL 015-060 COMMERCIAL ONLY
H = HORIZONTAL
V = VERTICAL
UNIT SIZE
006 - E,G
009 - E,G
012 - E,G
015 - E,G
018 - E,G
024 - E,G,H,F
030 - E,G,H,F
036 - E,G,H,F
042 - G,H,F,N
048 - G,H,F,N
060 - G,H,F,N
AVAILABLE
VOLTAGES
RETURN AIR OPTIONS
L = LEFT RETURN
R = RIGHT RETURN
V = LEFT RETURN, STAINLESS STEEL DRAIN PAN
W = RIGHT RETURN, STAINLESS STEEL DRAIN PAN
HEAT EXCHANGER OPTIONS
REVISION LEVEL
Non Coated Air Coil Tin-plated Air Coil
Copper Cupro-nickel Copper Cupro-nickel
Standard
C
N
A
J
Motorized Valve
T
S
U
W
E
ClimaDry®
P
D
F
A = CURRENT REVISION
VOLTAGE
G = 208-230/60/1
E = 265/60/1
H = 208-230/60/3
F = 460/60/3
N = 575/60/3
WATER CIRCUIT OPTIONS
0 = None
2 = HWG (Coil Only)
5 = Internal Secondary Pump
6 = HWG (Coil Only) w/Auto Flow Regulator 2.5 GPM/Ton
7 = HWG (Coil Only) w/Auto Flow Regulator 3.0 GPM/Ton
8 = Auto Flow Regulator 2.5 GPM/Ton
9 = Auto Flow Regulator 3.0 GPM/Ton
CONTROLS
C = CXM
D = DXM
L = CXM w/LON
M = DXM w/LON
N = CXM w/MPC
P = DXM w/MPC
CABINET INSULATION
1 = EXTENDED RANGE
2 = EXTENDED RANGE w/ULTRA QUIET
3 = STANDARD RANGE
4 = STANDARD RANGE w/ULTRA QUIET
NOTE: Some options/configurations not available on all series. Please consult Engineering Guides for model-specific options.
ClimaDry® II Option Notes:
1. Unit must have DXM control option. 460 volt unit units require a four wire power supply with neutral.
2. ClimaDry® II may not be combined with motorized water valve, internal secondary circulating pump, or automatic
flow regulator options.
3. Unit minimum entering air temperature while in the dehumidification, cooling, or continuous fan modes is
70ºF DB/61ºF WB. Operation below this minimum may result in nuisance faults.
4. A thermostat with dehumidification mode or thermostat and separate humidistat/dehumidistat is required for
activation and control of ClimaDry® II.
5. Downflow units and 575 volt units are not eligible for ClimaDry® II.
c l i m a t e m a s t e r. c o m
3