Download caution! - Climatemaster
Transcript
THE SMART SOLUTION FOR ENERGY EFFICIENCY Tr a n q u i l i t y ® ( T R ) S e r i e s R e v. : 0 7 / 1 8 / 1 3 Model Nomenclature - General Overview 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 TR H 036 A G C 3 0 C L B S S = STANDARD MODEL TYPE ® TR = TRANQUILITY HIGH EFFICIENCY 410A SUPPLY AIR OPTIONS CONFIGURATION B = BACK DISCHARGE, HORIZONTAL ONLY Y = BACK DISCHARGE, HIGH STATIC HORIZONTAL 015-060 COMMERCIAL ONLY T = TOP DISCHARGE, VERTICAL ONLY V = TOP DISCHARGE, HIGH STATIC VERTICAL 015-060 COMMERCIAL ONLY S = STRAIGHT DISCHARGE, HORIZONTAL ONLY Z = STRAIGHT DISCHARGE, HIGH STATIC HORIZONTAL 015-060 COMMERCIAL ONLY H = HORIZONTAL V = VERTICAL UNIT SIZE 006 - E,G 009 - E,G 012 - E,G 015 - E,G 018 - E,G 024 - E,G,H,F 030 - E,G,H,F 036 - E,G,H,F 042 - G,H,F,N 048 - G,H,F,N 060 - G,H,F,N AVAILABLE VOLTAGES RETURN AIR OPTIONS L = LEFT RETURN R = RIGHT RETURN V = LEFT RETURN, STAINLESS STEEL DRAIN PAN W = RIGHT RETURN, STAINLESS STEEL DRAIN PAN HEAT EXCHANGER OPTIONS REVISION LEVEL Non Coated Air Coil Tin-plated Air Coil Copper Cupro-nickel Copper Cupro-nickel Standard C N A J Motorized Valve T S U W E ClimaDry® P D F A = CURRENT REVISION VOLTAGE G = 208-230/60/1 E = 265/60/1 H = 208-230/60/3 F = 460/60/3 N = 575/60/3 WATER CIRCUIT OPTIONS 0 = None 2 = HWG (Coil Only) 5 = Internal Secondary Pump 6 = HWG (Coil Only) w/Auto Flow Regulator 2.5 GPM/Ton 7 = HWG (Coil Only) w/Auto Flow Regulator 3.0 GPM/Ton 8 = Auto Flow Regulator 2.5 GPM/Ton 9 = Auto Flow Regulator 3.0 GPM/Ton CONTROLS C = CXM D = DXM L = CXM w/LON M = DXM w/LON N = CXM w/MPC P = DXM w/MPC CABINET INSULATION 1 = EXTENDED RANGE 2 = EXTENDED RANGE w/ULTRA QUIET 3 = STANDARD RANGE 4 = STANDARD RANGE w/ULTRA QUIET NOTE: Some options/configurations not available on all series. Please consult Engineering Guides for model-specific options. ClimaDry® II Option Notes: 1. Unit must have DXM control option. 460 volt unit units require a four wire power supply with neutral. 2. ClimaDry® II may not be combined with motorized water valve, internal secondary circulating pump, or automatic flow regulator options. 3. Unit minimum entering air temperature while in the dehumidification, cooling, or continuous fan modes is 70ºF DB/61ºF WB. Operation below this minimum may result in nuisance faults. 4. A thermostat with dehumidification mode or thermostat and separate humidistat/dehumidistat is required for activation and control of ClimaDry® II. 5. Downflow units and 575 volt units are not eligible for ClimaDry® II. c l i m a t e m a s t e r. c o m 3