5500A Operator Manual 5-55. Programming the ISR, ISCR, and ISCE To read the contents of the ISR, send the remote command, ISR?. To read the contents of the ISCR0 or 1, send the remote command, ISCR0?, or ISCR1?. To read the contents of the ISCE0 or 1, send the remote command, ISCE0?, or ISCE1?. The 5500A Calibrator responds by sending a decimal number that represents bits 0 through 15. Every time you read the ISCR0 or 1, its contents are zeroed. The following sample program reads all five registers: 10 20 30 40 50 60 70 80 50 60 70 80 90 100 110 100 110 120 ! THIS PROGRAM READS THE ISR, ISCR, AND ISCE REGISTERS ! NOTE THAT THE ICSR? COMMANDS CLEAR THE ISCR CONTENTS PRINT @6, "ISR?" ! ASK ISR CONTENTS INPUT @6,A% ! RETRIEVE REGISTER CONTENTS FROM 5500A PRINT @6, "ISCR0?" ! ASK FOR AND CLEAR ISCR0 CONTENTS INPUT @6, B% ! RETRIEVE REGISTER CONTENTS FROM 5500A PRINT @6, "ISCE0?" ! ASK FOR ISCE0 CONTENTS INPUT @6, C% ! RETRIEVE REGISTER CONTENTS FROM 5500A PRINT @6, "ISCR1?" ! ASK FOR AND CLEAR ISCR1 CONTENTS INPUT @6, D% ! RETRIEVE REGISTER CONTENTS FROM 5500A PRINT @6, "ISCE1?" ! ASK FOR ISCE1 CONTENTS INPUT @6, E% ! RETRIEVE REGISTER CONTENTS FROM 5500A PRINT "ISR = ";A% ! DISPLAY ISR PRINT "ISCR0 = ";B% ! DISPLAY ISCR0 PRINT "ISCE0 = ";C% ! DISPLAY ISCE0 PRINT "ISCR1 = ";D% ! DISPLAY ISCR1 PRINT "ISCE1 = ";E% ! DISPLAY ISCE1 END Convert the returned variables into binary, and you can read the status of the instrument. For example if a register contains 4, its binary equivalent is: 00000000 00000100. Therefore, bit 3 (VBOOST) is set (1) and the rest of the bits are reset (0). By setting the bits in an ISCE register, you can mask (disable) the associated bits in the ISCR. For example, to cause an SRQ interrupt when the output has settled, bit 12 (SETTLED) in the ISCE1 register must be 1. (The ISCB bit must also be enabled in the SRE.) The following sample program loads a decimal 1024 into the ISCE, which sets bit 12 and resets the other bits: 10 20 30 40 50 60 ! THIS PROGRAM LOADS 00010000 00000000 BINARY INTO THE ISCE PRINT @6, "ISCE 4096" ! LOAD DECIMAL 4096 INTO ISCE PRINT @6, "ISCE?" ! READ BACK ISCE VALUE INPUT @6, A% ! " PRINT "ISCE = ";A% ! PRINT IT, IT SHOULD BE 4096 END 5-56. Output Queue The output queue is loaded whenever a query is processed, and holds up to 800 characters. The controller reads it with a statement such as a BASIC INPUT statement, removing what it reads form the queue. If the queue is empty, the 5500A Calibrator does not respond to the INPUT statement from the controller. The Message Available (MAV) bit in the Serial Poll Status Byte is 1 if there is something in the output queue and 0 if the output queue is empty. 5-42