Download CH? (Query Only)
Transcript
Commands Listed in Alphabetical Order AUXIn:PRObe:GAIN? (Query Only) This query-only command returns the gain factor of the probe that is attached to the AUX In input. The “gain” of a probe is the output divided by the input transfer ratio. For example, a common 10x probe has a gain of 0.1. Group Vertical Syntax AUXIn:PRObe:GAIN? Examples AUXIN:PROBE:GAIN? might return :AUXIN:PROBE:GAIN 0.1000E+00, indicating that the attached 10x probe delivers 0.1 V to the AUX In BNC for every 1.0 V applied to the probe input. AUXIn:PRObe:ID:SERnumber? (Query Only) This query-only command returns the probe serial number. Group Vertical Syntax AUXIn:PRObe:ID:SERnumber? Examples AUXIN:PROBE:ID:SERNUMBER? might return :AUXIN:PROBE:ID:SERNUMBER “B999999”, indicating that the probe serial number is set to B999999. AUXIn:PRObe:ID:TYPe? (Query Only) This query-only command returns the probe type. Group Vertical Syntax AUXIn:PRObe:ID:TYPe? Examples AUXIN:PROBE:ID:TYPE? might return :AUXIN:PROBE:ID:TYPE “TAP1500”, indicating that the probe type is set to TAP1500. DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual 2-91
Related documents
SEARCH:SEARCH
Tektronix DPO4000 User's Manual
3D - Rapid Electronics
Canon BJC80 - BJC 80 Color Inkjet Printer Specifications
Connect-Tek USB-2 Specifications
Handbuch
MEASUrement:MEAS? (Query Only)
Novell Automobile Parts 5250 User's Manual
Oscilloscope Programmer`s Reference
Programmer Manual
TRIGger:A:BUS:B