Download ITW
Transcript
Page 5-2 Revised 4/07 ITW Dynatec c. 2002 MR1300 APPLICATOR w. INTEGRATED FILTER Manual #40-43 Problem Possible Cause Solution Hot melt is coming out of the module’s “weep” holes 1. Module seals are damaged. 1. Replace seal cartridge or module, see instructions in this chapter. Applicator does not reach operating temperature 1. Hopper temperature setpoint is too low. 1. Change setpoint, see ASU manual. 2. Inoperative heater cartridge. 2. Check/ replace heater cartridge, see instructions in this chapter. 3. Inoperative temperature sensor. 3. Check/ replace sensor, see instructions in this chapter. 1. Applicator temperature setpoint is too high. 1. Change setpoint, see ASU manual. 2. Inoperative temperature sensor. 2. Check/ replace sensor, see instructions in this chapter. 1. Inoperative piston o-ring. 1. Replace o-ring, see instructions in this chapter. 2. O-rings located between module and service block are inoperative. 2. Remove module from block (see instructions in this chapter: “Replacement of Module”) and replace o-rings. 1. Adhesive pressure is too low. 1. a. For units without speed control: increase adhesive pressure at ASU. Applicator is too hot Air escapes from module Application pattern is erratic b. For units with speed control (tach follower): adjust pump speed control. 2. Adjust pattern controller. 2. See pattern controller manual for proper adjustment.