<IO Output Signal from the Servomotor>
9. Servo Finish Positioning
If the deviation pulse is less than the set value, it is recognized that the ram has reached the
position it be and “ON” is displayed. When it is normal, ON is displayed.
10. Servo Near Positioning
If the servomotor position is within the Servo Near Positioning range, “ON” is displayed. When it
is normal, ON is displayed.
11. Detection of Emergency
When the emergency stop switch is pressed, ON is displayed.
● Load Cell
Set the load meter at a position where load can be applied.
Press the home position return switch ([HOME] for the unit type) to return the ram to the
mechanical home position.
When the ram reaches the home position, lower it using the jog keys. The current position of the
ram and the current load will be displayed on the screen. Check that the value on the screen of
the machine matches that of the load meter.
Load Cell
Load Cell
Push Operation Switch
Press HOME Key
For Mechanical Initializing
Read Pos.
Read Load
Maintenance
35
0.000 mm
0.000 N
Electro Press JP Series 4