D40x40 / Navtec Navigator Maintenance RELIEVE SYSTEM HYDRAULIC PRESSURE Relieve all pressure in the hydraulic system before disconnecting the hoses or performing other work on the system. When loosening fittings in hoses where residual pressure may exist, slowly loosen the fitting until oil begins to leak. Wait for leaking to stop before disconnecting the fitting. Make sure all connections are tight and hoses are in good condition before applying pressure to the system. EN08402.L96 Some residual pressure will probably remain in the outrigger and rack angle hydraulic circuits due to pressure lock valve cartridges in the cylinders. N-L-OI76-NO92 _ ^ Use extreme caution when removing a cartridge. The cartridge will be released with great force if residual pressure remains in the cylinder. Do not stand in front of the cartridge when removing it. Safety Messages (01-10)