RLT and RL: Wrap the cable around the spool and insert it through
the cable fixing port. While firmly pulling the cable, use a torque
wrench with a 2 mm bit socket to tighten the cable pinch bolt to
0.9 N‚m (8 in-lb).
2 mm
RLT and RL
Cut the excess cable, leaving 30 mm protruding from the cable
fixing port. Install a cable end fitting and tuck the cable end into
the slot in the spool.
RLT and RL
RLT and RL
RLT and RL
28
CABLE INSTALLATION