Download SERVICE MANUAL
Transcript
2. The wattage of the 2 lamps is different. Make sure that the lamp having the correct wattage is attached by aligning the lamp with the holes on the heater lamp bracket. 3. Do not directly touch the glass sections of the lamps, and leave fingerprints or other marks. 6 7 6 7 [H] Upper/lower heat roller and cleaning roller 3 (1) Remove the fuser unit guard and jam processing unit. (2) Draw out the 2 heater lamps. (3) Completely loosen the 2 screws fixing the pressure springs. (4) Remove the front handle bracket (1 screw). (5) Remove the front stop ring and gear. (6) Remove the 2 front screws and take out the bearing. Bearing Stop ring (6) (6) (4) Handle bracket (7) Remove the timing belt. (8) Remove the rear stop ring and take out the pulley. Stop ring Timing belt Pulley 6570/5570 FUSER UNIT 14 - 14 Mar. 1999 © TOSHIBA TEC