Download HCD-EH15
Transcript
HCD-EH15 SECTION 5 MECHANICAL ADJUSTMENTS PRECAUTION 1. Clean the following parts with a denatured-alcohol-moistened swab: record/playback head pinch roller erase head rubber belts capstan idlers 2. Demagnetize the record/playback head with a head demagnetizer. (Do not bring the head magnetizer close to the erase head.) 3. Do not use a magnetized screwdriver for the adjustments. 4. After the adjustments, appiy suitable locking compound to the parts adjusted. 5. The adjustments should be performed with the rated power supply voltage unless otherwise noted. TORQUE MEASUREMENT Mode FWD FWD Back Tension FF Torque meter CQ-102AS CQ-102C CQ-201AS REW CQ-201B Meter reading 2.0 – 8.0 mN • m (20 – 80 g • cm) (0.28 – 1.12 oz • inch) 0.15 – 0.6 mN • m (1.5 – 6.0 g • cm) (0.021 – 0.083 oz • inch) 5.0 – 17.7 mN • m (50 – 177 g • cm) (0.7 – 2.48 oz • inch) 5.0 – 17.7 mN • m (50 – 177 g • cm) (0.7 – 2.48 oz • inch) TAPE TENSION MEASUREMENT Mode FWD Torque meter Meter reading CQ-403A more than 80 g (more than 2.82 oz) SECTION 6 ELECTRICAL ADJUSTMENTS DECK SECTION 0 dB=0.775 V 1. Demagnetize the record/playback head with a head demagnetizer. 2. Do not use a magnetized screwdriver for the adjustments. TEST TAPE Tape Signal Used for P-4-A063 6.3 kHz, –10 dB Azimuth Adjustment RECORD/PLAYBACK HEAD AZIMUTH ADJUSTMENT Procedure: 1. Mode: Playback test tape P-4-A063 (6.3 kHz, –10 dB) MAIN board PHONES jack (J102) level meter set + – 2. Turn the adjustment screw and check output peaks. If the peaks do not match for L-CH and R-CH, turn the adjustment screw so that outputs match within 1dB of peak. within 1dB L-CH peak within 1dB Output level Screw position R-CH peak L-CH peak Screw position R-CH peak 3. Mode: Playback test tape MAIN board P-4-A063 PHONES jack oscilloscope (6.3 kHz, –10 dB) (J102) V set H waveform of oscilloscope in phase 45° good 90° 135° 180° wrong 4. After the adjustments, apply suitable locking compound to the pats adjusted. 10