Page 2 American Metal Ware Volume Banquet Brew Systems 5” 4” 30” 4” 5” T C 8 5/8” 10 1/4” W 35” 45” 8 5/8” 10” C 5” 81” 6 FOOT, 120V AC, 3 WIRE CORD & PLUG ON EACH URN BREW AND HEAT CONTROLS 12” 1” 1/2 “ NPT STEAM OUTLET 1/2” NPT STEAM INLET C 1” 6” ON-OFF SWITCH ELECTRIC HEAT ONLY. 40 GAL. MODEL 99040E FOR AMV 60, 450 LBS. WHEN FULL, OR 80 GAL. MODEL 99060E FOR AMV 80, 625 LBS. WHEN FULL. HOLDING URN: /8” NPT HOT WATER INLET 3 MODEL 91119 ELECTRIC OR STEAM HEAT. WITH (2) 10 GAL. LINERS; (2) BBS19 BREW BASKETS FOR (25-11) PAPER FILTERS OR (17-9) MUSLIN BAG; (2) BOTTOM LINER FILTER SCREENS. C T 15” 27” 31” C 35” 6” C 17 1/2” 2” 8 3/4” 2” HOT WATER SPRAY RINSE HOSE LRO 1 5 4 3 2 BY DATE 11-23-81 5 1/4 WAS 6 NO. REVISIONS EXTERNALLY MOUNTED BLANKET HEATER WITH BUILT-IN THERMOSTAT FALSE BOTTOM C = COFFEE FAUCT W = WATER FAUCET T = THERMOMETER 32 1/4” for AMV 60 40 1/2” for AMV 80 CALIBRATED GAGE OVERFLOW STANDPIPE INSULATED COVERS 5 1/4” ALL FAUCETS 1 10 1/2” 13 3/4” 17 3/4” 1” LEG LOCATIONS SIMILAR ON BREW URN /8” NPT HOT WATER CONNECTION AT BOTTOM BREW URN: ALL AMV 60 AND 80 SYSTEMS ARE DUAL WALL INSULATED. TRANSFER PUMP SPRAYOVER PUMP TRANSFER TIMER STOP/START SWITCHES 37” TRANSFER BALL VALVE PUMP HOUSING HAS REMOVABLE SIDE - FRONT COVER TO PROVIDE EASY SERVICE ACCESS ELECTRIC INPUT UTILITY CONNECTIONS ARE FLUSH WITH BOTTOM J B NPT HOT WATER INLET (140OF) COFFEE TRANSFER HOSES (1) 3 FOOT (1) 6 FOOT 3 208 240 208 240 480 VOLT VOLT VOLT VOLT VOLT - 1 1 3 3 3 PH. PH. PH. PH. PH. 2 2 3 3 3 WIRE WIRE WIRE WIRE WIRE 208 72 42 15KW 240 63 36 480V -18 LRO,GRM R.8 LRO TRACES CHK’D DRAWN BY . APPS DATE SCALE 8-5-81 N.T.S. B-290 DRAWING NO. MATERIAL HIGH VOLUME/BANQUET COFFEE BREWING/HOLDING SYSTEM. MODELS AMV 60 AND AMV 80 AMERICAN METAL WARE C) TOTAL BOILER HORSEPOWER = 2.3 B) MAXIMUM STEAM DEMAND LBS. PER HOUR TOTAL = 70 A) STANDARD OPERATING STEAM PRESURE = 10 - 25 PSI 4. EACH BREW URN - STEAM HEAT KW Heater Size Elec. Supply Volts Amps Drawn 1 Ph. Amps Drawn 3 Ph. B) TOTAL HEATER LOAD FOR EACH BREW URN A) SPECIFY SERVICE: 3. BREW URN - ELECTRIC HEAT A) TOTAL PUMP/CONTROL LOAD FOR BREW URN = 15 AMP, FOR EACH SYSTEM = 30 AMP. B) TOTAL HEATER LOAD FOR HOLDING URN = 3 KW/16.5 AMP 2. SEPARATE 120V. SINGLE PHASE, 3 WIRE, 20 AMP OUTLET REQUIRED FOR BREW URN AND FOR HOLDING URN. USE NEMA RECEPTACLE NO 5-20R, 3 WIRE CORD AND PLUG SUPPLIED ON EACH URN 1. BREW URN AND HOLDING URN REQUIRE CONNECTION TO HOT WATER (140OF) SUPPLY, 3/8” NPT. UTILITY DATA AMV 60/80