Attention Please:
American Changer is now building in a Surge Suppressor on every main logic board made after
September 1st, 1998. This will help eliminate power related noise problems for our customers. It will
not protect you from large voltage spikes or lightning strikes over 150VAC.
If this is a concern for your area of business, we recommend purchasing a surge protector locally
NOTE: A POWER STRIP IS NOT A SURGE PROTECTOR.
Thank You,
American Changer Corp.
(888) 741-9840
MAIN LOGIC BOARD (ON BACK WALL OF CABINET)
QUICK CODE FAULT DEFINITIONS
BILL METER /
ERROR CODES
DIP
SWITCHES
00101
DUMP
BUTTON
RIGHT HOPPER
ERROR CODE.
LEFT DIGIT
ALWAYS “0”.
IGNORE!
LEFT HOPPER
ERROR CODE.
Press the “DUMP” Button before turning off changer. Match the code to
samples below to find out why the hopper(s) were shut down
RIGHT HOPPER ERRORS
LEFT HOPPER ERRORS
0 0 0 0 0 - NO ERRORS
0 0 1 0 0 - LOW COIN
0 0 2 0 0 - EXIT WINDOW JAM
0 0 3 0 0 - BAD HOPPER BOARD
0 0 4 0 0 - JAMMED
0 1 0 0 0 - JACKPOT PREVENTED
0 0 0 0 0 - NO ERRORS
0 0 0 0 1 - LOW COIN
0 0 0 0 2 - EXIT WINDOW JAM
0 0 0 0 3 - BAD HOPPER BOARD
0 0 0 0 4 - JAMMED
0 0 0 1 0 - JACKPOT PREVENTED
IF THE “EMPTY” LED IS LIT, LOOK FOR CODES FOR BOTH HOPPERS TO BE DISPLAYED!
2