Download User Manual
Transcript
5 ELECTRONIC CONTROLLER 5.1 Microprocessor Display 1 3 2 Figure 6: Microprocessor Display There are three LED buttons which display the operating status of the controller: Key 1 2 3 Button Function ‘UP’ key. Light indicates COMPRESSOR is running. Flashing indicates manual request of Continuous Cycle is delayed by the compressor timed routine. INCREASES Set-Point values. Enables compressor CONTINUOUS CYCLE when pressed for more than 5 seconds. ‘DOWN’ key. Light indicates DEFROSTING. DECREASES Set-Point values. Activates a manual DEFROST CYCLE when pressed for more than 5 seconds. ‘SET’ key. Light indicates an ALARM (Press to mute audible alarm). Flashing indicates the corresponding function is delayed by a timed routine. DISPLAYS the Set-Point value. During normal working conditions, the display shows the value measured by the ambient probe or by the second probe (parameter /4). If the alarm is activated, the relative code is displayed. YARRA YA850i & YA1700i Installation, Operation and Service Manual 21