Download Phaser 790/DocuColor 2006 Service Manual
Transcript
REP 6.19 Belt REP 6.20 Lamp Parts List on PL 16.4 Removal Parts List on PL 16.5 Removal WARNING WARNING To avoid personal injury or shock, do not perform repair activities with the power switch on or electrical power applied to the machine. To avoid personal injury or shock, do not perform repair activities with the power switch on or electrical power applied to the machine. 1. Switch off the machine power and disconnect the machine Power Cord. 1. Switch off the machine power and disconnect the machine Power Cord. 2. Remove the Carriage Motor (REP 6.18). 2. Remove the Platen Glass (REP 6.1). 3. Remove the Belt (Figure 1). 3. Move the Full-rate Carriage so that it is aligned with the notches in the center of the scanner frame. 4. Remove the Lamp (Figure 1). 1 Remove the Belt Scanner frame Notches 1 Disconnect the connector 2 Remove the screw and then remove the Lamp by turning it in the direction indicated Figure 1 Removing the Belt Replacement 1. Perform the procedure for removal in reverse. Figure 1 Removing the Lamp Replacement 1. Repairs and Adjustments REP 6.19, REP 6.20 10/00 4-50 Perform the procedure for removal in reverse. Initial Issue Phaser 790/DocuColor 2006
Related documents