Download Phaser 790/DocuColor 2006 Service Manual
Transcript
REP 6.11 PWB Box 8. Parts List on PL 16.1 Removal 1 WARNING To avoid personal injury or shock, do not perform repair activities with the power switch on or electrical power applied to the machine. 1. Switch off the machine power and disconnect the machine Power Cord. 2. Remove the Platen Glass (REP 6.1). 3. Remove the ADF Assembly (REP 5.1). 4. Remove the Right Cover from the Scanner (REP 6.2). 5. Remove the Rear Cover from the Scanner (REP 6.4). 6. Remove the Advanced Features Memory PWB (REP 6.16). 7. Remove the connector cover (Figure 1). Disconnect five connectors from the ICM Main PWB (Figure 2). On the right side of the Scanner, disconnect the Ribbon Cable and connectors 2 3 At the rear of the Scanner, disconnect the connectors (3) 1 Loosen the screw on the bracket underneath the Ribbon Cable Figure 2 Disconnecting the Connectors Remove the screws (2) and connector cover Figure 1 Removing the Connector Cover Initial Issue Phaser 790/DocuColor 2006 10/00 4-43 Repairs and Adjustments REP 6.11