REP 6.11 PWB Box
8.
Parts List on PL 16.1
Removal
1
WARNING
To avoid personal injury or shock, do not perform repair activities with the power switch
on or electrical power applied to the machine.
1.
Switch off the machine power and disconnect the machine Power Cord.
2.
Remove the Platen Glass (REP 6.1).
3.
Remove the ADF Assembly (REP 5.1).
4.
Remove the Right Cover from the Scanner (REP 6.2).
5.
Remove the Rear Cover from the Scanner (REP 6.4).
6.
Remove the Advanced Features Memory PWB (REP 6.16).
7.
Remove the connector cover (Figure 1).
Disconnect five connectors from the ICM Main PWB (Figure 2).
On the right side of the
Scanner, disconnect
the Ribbon Cable and
connectors
2
3
At the rear of the
Scanner, disconnect
the connectors (3)
1
Loosen the screw
on the bracket
underneath the
Ribbon Cable
Figure 2 Disconnecting the Connectors
Remove the screws (2) and connector cover
Figure 1 Removing the Connector Cover
Initial Issue
Phaser 790/DocuColor 2006
10/00
4-43
Repairs and Adjustments
REP 6.11