GENERAL
Tyler Refrigeration
canopy joint trim (2) with screws at top
and bottom as shown.
2. Install top pull-up access cover (4) to
cases (5) with four screws (5).
Horizontal Joint Trim Installation
9. Install all pull-up access covers (3), front
duct (2), bottom tray (1) and/or front
cladding (4), where applicable.
10. Remove shipping tape from all fluorescent lamps.
Trim Installation/Alignment
Upper Trim Installation
1. Apply bead of caulking compound from
the Filler Kit to the top of each horizontal
joint (1). If gap at horizontal joint is too
large, pull together with sheet metal
screws (2) or pop-rivets (3).
NOTE
Loosen screws as needed to line-up the
canopy hoods. Hoods are adjustable in all
directions.
If additional sealing is preferred, 2” wide
duct tape can be applied to the top of the
internal bottom joint between cases. The
tape will be covered by the horizontal joint
trim. Duct tape is not furnished.
1. For interior joint trim, use a screwdriver
through top pull-up access hole to position the canopy hood backer (1) so it
bridges any gap between the canopy
hood case joint (3). For exterior joint
trim, position canopy joint trim (2) over
any gap between the canopy hood joint
(3). Secure canopy hood backer (1) or
2. Apply sealer to horizontal joint trim (4)
and install joint trim (4) on the horizontal
joint (1).
Page G-10
Front Glass Trim Installation
The following instructions can be used to
install the front glass trim on cases with 6” or
14” front glass.
January, 1999