Diagnostics m. Click Yes. The following message box displays: n. Click No to exit and close the HyperTerminal application. o. Power off the maintenance terminal. p. Disconnect the RS-232 modem cable from the switch and the maintenance terminal. Replace the protective cap over the maintenance port. Was event code 433 reported? NO ↓ YES An unrecoverable Ethernet fault (CTP failure) occurred. Because the CTP card is not a FRU, CTP failure requires replacing the switch. Contact the next level of support. MAP 0500: Fan and CTP Failure Analysis This MAP describes fault isolation for the CTP (which is not a FRU) and fan FRUs. Failure indicators include: 2–58 • The amber LED on a fan illuminates. • The amber emulated LED on a fan graphic at the Hardware View illuminates. • A blinking red and yellow diamond (failed FRU indicator) displays at the Product View or Hardware View. • An event code recorded at the switch Event Log or the Embedded Web Server event log. • A Failed or Not Installed message associated with a fan at the Embedded Web Server interface. edge switch 2/32 service manual