Download hp StorageWorks edge switch 2/32 service manual

Transcript
Diagnostics
m. Click Yes. The following message box displays:
n. Click No to exit and close the HyperTerminal application.
o. Power off the maintenance terminal.
p. Disconnect the RS-232 modem cable from the switch and the maintenance
terminal. Replace the protective cap over the maintenance port.
Was event code 433 reported?
NO
↓
YES
An unrecoverable Ethernet fault (CTP failure) occurred. Because the CTP
card is not a FRU, CTP failure requires replacing the switch.
Contact the next level of support.
MAP 0500: Fan and CTP Failure Analysis
This MAP describes fault isolation for the CTP (which is not a FRU) and fan FRUs.
Failure indicators include:
2–58
•
The amber LED on a fan illuminates.
•
The amber emulated LED on a fan graphic at the Hardware View illuminates.
•
A blinking red and yellow diamond (failed FRU indicator) displays at the Product
View or Hardware View.
•
An event code recorded at the switch Event Log or the Embedded Web Server event
log.
•
A Failed or Not Installed message associated with a fan at the Embedded
Web Server interface.
edge switch 2/32 service manual