Download LTH - Hussmann

Transcript
1-5
P/N 0506146_D
DOOR SEAL
SERIAL PLATE LOCATION
Check that hinge doors close automatically by
opening the door 45 degrees and releasing.
Ensure door closes and gasket seals door shut.
To adjust the torque applied to the hinged
door:
The serial plate is located at the interior left
side of the merchandiser’s cabinet. It contains
all pertinent information such as model, serial
number, amperage rating, refrigerant type and
charge.
1. Place a wrench on each of the two lower
support nuts located at the bottom hinge.
DOOR LOCK
2. Loosen the lower nut while holding the
upper nut in place.
A door lock is standard on all doors. The key
is tie-wrapped to the door handle at shipment.
3. Torque is increased or decreased by rotating
the top nut. After adjustments are made, tighten the bottom nut while holding the upper nut
in place. Torque bottom nut to a minimum of
20 ft-lb.
Adjust Door Closing Torque
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.