Download SurroundControl 31960
Transcript
7.2.10 | The Mono Key This key switches the mono signal to the channel(s) selected with the Mono Mode function in the Monitoring instrument (MONITORING). The function selected in the Toolbar remains activated until the Close button is selected. In this way, the effects of different settings can be compared. In window 4 (Status Box), the message „Mono active“ is displayed. Please proceed as follows to select the Mono mode : 1. Press the INSTR button until window 3 gets the white frame. 2. Press the MODE button on the left to switch from Function Select mode to Instrument Select mode. 3. Press button 7 labelled MONITORING. The Monitoring instrument is displayed in window 3 and the Toolbar switches to the Function Select mode for the Monitoring instrument. 4. Press button 1 labelled Mono Mode. Now you can select the channels or channel groups to which the mono signal should be switched. 5. After having selected your preferred channel or channel group, press the Close button to get back to the Monitoring instrument functions. 6. Press the M key. The mono signal is switched to the selected channel or channel group. EN 7.2.11 | The Volume control This control adjusts the listening volume. The volume control sensitivity (Vol Sens) can be set in the MONITORING instrument spreading the level range that can be passed through by a fast turn of the volume control. In all modes, pressing the Volume control retrieves and sets the preset value stored with the CS channel key. The Downmix-Direct-Out signals DLo, DRo and DMo are not affected by the volume control setting. The volume control is also used in the CAL instrument for setting trim and delay values for individual channels. To do so, hold down the Trim or Delay button and simultaneously turn the volume control. In Multi-Channel modes, the control is used to select one of the Listening Groups. If the Adding Mode, push volume knob for global reset check box is activated on the Key Settings menu, all channels can be set back to the basic position by pressing the volume control. Please proceed as follows to select the volume control sensitivity for fast movements: 1. Press the INSTR button on the right until window 3 gets the white frame. 2. Press the MODE button on the left to switch from Function Select mode to Instrument Select mode. 3. Press button 7 labelled MONITORING. The Monitoring instrument is displayed in window 3 and the Toolbar switches to the Function Select mode for the Monitoring instrument. SurroundControl 31900/31960 Series 4. Press button 5 labelled Vol Sens until you have selected the sensitivity option you prefer: low (L) for a small volume level range that can be passed through with one turn, middle (M) for a middle range or high (H) for a large range. The selected option is highlighted on the button in the Toolbar. 5. Now you can use the volume control with the selected sensitivity. 7 | Control | 7.2 | Using the Control Elements EN-45