Download SurroundControl 31960

Transcript
8.15.2 | Changing parameters of the BLITS instrument
For the use of the BLITS instrument as a generator for broadcasting, you can route the channels of the BLITS test tone sequence to the outputs you want to use. Also, you can prepend a wave file with your station identification sound to the sequence.
Please proceed as follows to define the outputs for the BLITS generator:
1.
Press MENU button. The unit changes to menu mode.
2.
Select the Edit selected preset button.
3.
Select the Local Input/Output Routing and Instrument
Settings menu tab.
9.
4.
Select the Monitoring Output Routing button.
5.
Select the column representing the output connector
you want to use for the output of the generated BLITS
sequence.
8.
Open the combo boxes labelled Direct Out 3, Direct Out
4 or Analog Direct Out that are needed for the BLITS
channels and select one of the BLITS labelled channels
(Blits L, Blits R, …, Blits RS).
Repeat steps 6 - 9 until all channels are assigned.
10. Select the Save & Exit button to store the changes and
leave the menu. The Save Preset menu page is displayed.
11. Select a User Preset of your choice to store your settings
in.
12. Select the Change name button to edit the preset name.
A keyboard display is shown to enter a new preset name
(6 characters maximum).
6.
Open the combo boxes of the desired channels you want
to be the BLITS outputs.
7.
To select the outputs in the Digital Out 3 and Digital Out
4 columns and the outputs in the Analog Out column,
13. Select the Save & Exit button again. All changes are
select Use direct out in the corresponding combo boxes.
stored and the unit returns to normal operation.
Please proceed as follows to activate the BLITS sequence:
1.
Press MENU again. The unit changes to menu mode.
6.
2.
Select the Generator and Surround Ident Settings
menu tab. The Generator and Surround Ident Settings
menu is shown.
If an offset is needed for the digital or analog outputs, use
the Digital offset or Analog offset list box in the Surround
Ident area and enter a value between -12 and +12 dB.
7.
Select the Save & Exit button to save the setup and to
leave the menu. The dialog box Save Global Settings? is
shown.
8.
Select Save & Exit button again to store the changes and
to return to normal operation with the outputs routed. The
BLITS sequence is now permanently routed to the defined
outputs.
3.
Check the Enable option in the Surround Ident area.
4.
Open the Format combo box in the Surround Ident area.
5.
Select the BLITS 5.1 option.
SurroundControl 31900/31960 Series
8 | Instruments (Display Modes) | 8.15 | The BLITS Instrument EN-109
EN