Download SurroundControl 31960
Transcript
• • • • Standard Settings Digital This combo box applies to the parameters grouped directly below it. After selecting Digital, ARD or True Peak, these combo boxes are automatically set to values corresponding to the Digital, ARD or True Peak standards. After editing any of these combo boxes manually (except the Operation indicator area combo box), the text „Non Standard“ is displayed in the Standard Settings Digital combo box. Reselecting Digital, ARD or True Peak automatically resets all parameters grouped below to the standard values of these presets. Scale This combo box is used to select the preferred scale: • TP60 (–60 dBFS to +3 dBFS, Standard Settings Digital, selection: True Peak) • TP20 (–60 dBFS to +3 dBFS) • Dig60dB (–60 dBFS to 0 dBFS, Standard Settings Digital, selection: Digital) • Dig20dB (–20 dBFS to 0 dBFS) • Dig+18 dB... 0 dB (0 dBFS = +18 dB) • Dig+18 dB... 0... –18 dB (0 dBFS = +18 dB) • Dig+20 dB... 0... –40 dB (0 dBFS = +20 dB) • ARD +9 dB... –60 dB (0 dBFS = +9 dB, Standard Settings Digital, selection ARD) • <q> DIN 5 dB (quasi-DIN scale, –9 dBFS = 0 dB) • <q> DIN 10 dB (quasi-DIN scale, –9 dBFS = 0 dB) • <q> ARD +9 dB... –60 dB (quasi-DIN scale, 0 dBFS = +9 dB) • <q> Zoom +/– 10 dB (quasi-DIN scale, –9 dBFS = 0 dB) • <q> Zoom +/– 1 dB (quasi-DIN scale, –9 dBFS = 0 dB) • <q> Nordic (quasi-Nordic scale, –9 dBFS = +6 dB) • <q> British IIa (quasi-British scale, –10 dBFS = “6”) • <q> British IIb (quasi-British scale, –10 dBFS = +8 dB) Integration time This combo box is used to select the integration time of the level display: 10 ms (Standard Settings Digital, selection ARD) • • 20 ms • 1 ms • 0.1 ms • Sample (Standard Settings Digital, selection Digital) • 150 ms DC-Filter This combo box sets the DC filter. You can switch the filter off (Off) or set it to 5 Hz (standard settings digital), 10 Hz or 20 Hz. SurroundControl 31900/31960 Series • Headroom This list box sets the beginning of the headroom in the range between –20 dBFS and 0 dBFS. The digital standard setting is –9 dBFS. NOTE - The headroom of the ARD +9 dB...–60 dB scale is fixed to –9 dBFS. Choosing a different value in the Headroom list box has no effect. • Operation indicator area This list box sets the area where the indicator for the operating area is activated. Values between –20 dB and 0 dB are available. The digital standard setting is 0 dB. • Peak Hold fallback time This combo box is for setting the hold time for the peak hold display. Options: 1 s, 2 s, 4 s, 10 s, 20 s, 30 s and Manual Reset. With Manual Reset selected, you can reset the peak hold display with the Reset function in the Loudness Meter. • Mode This combo box is used for switching the Peak Hold function on or off. Options: Normal, Peakhold. • Bar Style This combo box selects the way the PPM and Loudness bargraphs are combined in the Program Meter display. Options: Loudness + U-Type PPM (narrow PPM bargraphs left and right of the loudness bargraph), Loudness + PPM Spot (PPM spots left and right of the loudness bargraph), and Loud + PPM Dual (PPM and loudness bargraphs of same width side by side). • Peakhold enabled These check boxes are used to activate the Peakhold displays for the PPM and Loudness bargraphs. Available options: PPM (for peakmeter bargraphs), Loudness (for loudness bargraphs). Loudness ... • Operation indicator area This list box sets the area where the indicator for the operating area is activated. Values between –20 dB and 0 dB can be entered. The digital standard setting is 0 dB. • Numeric This option is used to activate numerical displays for the PPM or Loudness bargraphs. Options: Off, PPM, Loudness. 9 | Menu | 9.4 | Input/Output Routing: The Global Routing Settings EN-149 EN