Download Manuel d'instructions
Transcript
For correct operation of the radio receiver section, when using two or more control units it is good practice to install them at a minimum distance of 3 metres from one another. All operations that require the control unit box to be opened (connection of cables, programming, etc.) must be carried out by expert personnel at the time of installation. For all further operations that require the box to be re-opened. IMPORTANT FOR THE USER • The device must not be use by children or people with reduced psychophysics abilities, or at least in case they are supervised or educated on the operation and its use. • Do not allow the children to play with the device and keep them out from the remotes. • ATTENTION! preserve this manual of instructions and respect the important safety prescriptions in it contained. The non-observance of these prescriptions could provoke damages and serious accidents. Examine frequently the plant to notice possible signs of damage. Don't use the device if an intervention of reparation is necessary. 10.1 TECHNICAL CHARACTERISTICS Back-up Battery input: Flashing light output: Operator outputs: Photocells power supply: Working temperature: Radio receiver: Transmitters: Max TX codes stored in memory: Board dimensions: 24 V 7A/h max. 4 W max. 24 V 24V 1 x 50 W max. 24V 5 W max. -20 ÷ 50 °C 433 Mhz 18 Bit or Rolling Code 120 (CODE or PED CODE) 100x105 mm. 10.3 ELECTRICAL CONNECTIONS CN1: BATT+24V: BATT-24V: LAMP+24V: LAMP-24V: MOT1+: MOT1-: CN2: STOP: GND: FOTO+: GND: FCC: GND: FCA: DS1: GND: PP: ANT-: ANT+: CN3: L: N: +24V Back-up Battery input –24V Back-up Battery input. +24V Flashing Light Output. –24V Flashing Light Output. Operator 1 + Output. Operator 1 – Output. Emergency stop input (NC) Common GND input Photocells Control and Power Supply (24V 5W). Photocells Control and Power Supply (GND). Operator Closing Limit Switch Input (NC). Common GND input Operator Opening Limit Switch Input (NC). Safety Device Input (NC). Common GND input Pedestrian Pushbutton open-close command input (NO). Antenna Ground Input. Antenna Hot pole input. 230 V 230 V line input (phase). line input (neutral). • Connection of the Y power cord. 10.4 FUNCTIONAL CHARACTERISTICS OPERATION: When either the remote or the low voltage pushbutton panel are used to control the barrier, operation is as follows: the first command opens the barrier until motor time elapses or the arm reaches its opening limit position; the second command closes the barrier; if another command is transmitted during the Opening movement, the control unit disregards the command; if a command is transmitted during the Closing movement the control unit reverses the movement direction. AUTOMATIC CLOSING: The control unit can be set up to close the barrier automatically without sending any additional commands. Selection of this type of operation is described in Pause time programming mode. EMERGENCY STOP INPUT: The control unit allows the connection of an emergency stop pushbutton (NC). Pressing this pushbutton irrespective of the current operating mode of the control unit will cause barrier movements to stop immediately. An additional barrier movement command will be valid, provided the emergency stop input is deactivated and, in any case, the control unit will perform the barrier opening cycle after preflashing for 5 seconds. PHOTOCELLS: Photocells can be powered by and connected to the control unit in accordance with directive EN 12453. • Input DS1 (NC) Tripping of the photocells during opening is disregarded, while during closing it causes reversal of the direction of movement. OPENING AND CLOSING LIMIT SWITCHES: The control unit allows the connection of Opening and Closing limit switches (NC). Tripping of the limit switches in the associated operating cycles causes immediate stopping of barrier movement. ADJUSTMENT OF MOTOR FORCE DURING THE “NORMAL” CYCLE: The electronic control unit is equipped with a “SPEED” trimmer for adjustment of Motor Force during the Normal cycle. Adjustment can be performed in a range of between 50% and 100% of maximum force during the Normal cycle. DECELERATION: The operators deceleration function is used to prevent the moving beam from slamming at speed into the limit stops at the end of the opening and closing strokes. During Operator Time programming (see Main menu) the control unit also allows programming of deceleration in the desired points (immediately before full opening and full closing); in addition, using the “DELAY” trimmer the force intensity can be adjusted during the deceleration phase. COMUNELLO ®Copyright 2015 - All rights reserved 21 ENGLISH protection against failure of anti-crushing protective devices according to Category 2 in compliance with the prescriptions of EN 12453 point 5.1.1.6. It follows that if the safety devices are not connected or are faulty, operation of the control unit will be inhibited. •The device can be used by children no older than 8 years old and people with reduced physical, sensory or mental capabilities, or lack of experience or without the required knowledge, but only under surveillance or after having received instructions about the safe use of the device and the hazards inherent in it. Children should not play with the device. Cleaning and maintenance should not be carried out by children without supervision.