Download REFERENCE & INSTALLATION MANUAL
Transcript
4.5 LOCK MASTER CODE Section [127] = System Options Option [4] OFF = Lock System Master Code Disabled (default) Option [4] ON = Lock System Master Code Enabled With this feature enabled, the control panel will lock the System Master Code (001). This means that pressing the System Master Code cannot be deleted but it can be changed. 4.6 DURESS CODE Section [127] = System Options Option [6] OFF = Duress Code Disabled (default) Option [6] ON = User Code 048 becomes a Duress code With this feature enabled, User Code 048 becomes a Duress Code. When forced to arm or disarm their system, users can enter a Duress Code (User Code 048) to arm or disarm the system which can immediately transmit a silent alert to the Central Station, transmitting the duress report code programmed in section [196]. S PECTRA S ERIES 19