15.2 Table of I/O Number Allocation 15.2.1 I/O Allocation of FP-X Control Unit The I/O allocation of the FP-X control unit is fixed. I/O numbers Type of control unit Number of allocation Input (8 points) FP-X C14 control unit Output (6 points) Input (16 points) FP-X C30 control unit Output (1 points) FP-X C60 control unit Input (32 points) Output (28 points) I/O number X0 to X7 Y0 to Y5 X0 to XF Y0 to YD X0 to XF X10 to X1F Y0 to YD Y10 to Y1D 15.2.2 FP0 Expansion Unit Allocation The FP-X expansion unit is installed on the right side of the FP-X control unit. I/O numbers (when installed as the first expansion unit) Type of expansion unit Number of allocation Input (8 points) FP-X E16 expansion I/O unit Output (8 points) Input (16 points) FP-X E30 expansion I/O unit Output (14 points) Note) E16R cannot be connected on the right side of E16R. I/O number X300 to X307 Y300 to Y307 X300 to X30F Y300 to Y30D 15.2.3 FP0 Expansion Unit Allocation Only one expansion FP0 adapter can be connected at the last position of the FP-X expansion bus. The I/O allocation varies depending on the installation location of the expansion FP0 adapter Expansion location Expansion unit 1 Expansion unit 2 Expansion unit 3 X300 to X31F X320 to X33F X340 to X35F Expansion 1st unit Y300 to Y31F Y320 to Y33F Y340 to Y35F X400 to X41F X420 to X43F X440 to X45F Expansion 2nd unit Y400 to Y41F Y420 to Y43F Y440 to Y45F X500 to X51F X520 to X53F X540 to X55F Expansion 3rd unit Y500 to Y51F Y520 to Y53F Y540 to Y55F X600 to X61F X620 to X63F X640 to X65F Expansion 4th unit Y600 to Y61F Y620 to Y63F X640 to X65F X700 to X71F X720 to X73F X740 to X75F Expansion 5th unit Y700 to Y71F Y720 to Y73F Y740 to Y75F X800 to X81F X820 to X83F X840 to X85F Expansion 6th unit Y800 to Y81F Y820 to Y83F Y840 to Y85F X900 to X91F X920 to X93F X940 to X95F Expansion 7th unit Y900 to Y91F Y920 to Y93F Y940 to Y95F X1000 to X101F X1020 to X103F X1040 to X105F Expansion 8th unit Y1000 to Y101F Y1020 to Y103F Y1040 to Y105F Note) The ranges of the I/O numbers which are actually used differ depending on the units. 15-13
Related documents
Panasonic FP0R Series PLCs User`s Manual
User Manual
Panasonic FP-X Programmable Controller User`s Manual
PROGRAMMABLE CONTROLLER FP0R User's Manual
Sistema de transmisión trasero
FP0 CC-Link Slave Unit - Panasonic Electric Works
USER`S MANUAL
USER`S MANUAL
USER`S MANUAL
Albatros Heat pump controller User Manual RVS61.843 AVS75.370
Icon
PROGRAMMABLE CONTROLLER FP