Download Operating Manual, EXTRA
Transcript
1. INSPECTION Each shipment should be carefully checked against the bill of lading or packing slip. The shipping receipt should not be signed until all items listed on the bill of lading have been accounted for. Check carefully for concealed damage. Any shortage or damages should be reported to the delivering carrier. Damaged material becomes the delivering carrier’s responsibility, and should not be returned to the manufacturer unless prior approval is given to do so. Warning: This equipment contains a refrigerant which may harm the public health and environment by destroying ozone in the upper atmosphere. Venting or release of certain refrigerants to the atmosphere is illegal. Refrigerant recovery devices must be used when servicing this unit. Consult your local codes for requirements. Warning: Do not service this unit before disconnecting all power supplies. 2. INSTALLATION REQUIREMENTS: Dedicated power line , 115v, 60Hz, 20 Amp Recommended ambient temperature range 60F-90F Adequate air circulation as follows: - air condenser cannot be obstructed or covered in any way - no filters allowed to be used with the unit 3. SPECIFICATION Name Unit Part Number EXTRA 1/2HP EXTRA 3/4HP EG-1/2P EG-3/4P Maximum Distance Ft up to 250' up to 450' Capacity, (evap 20F) BTU/hr 3250 4415 Glycol tank capacity Gal 15 15 Dedicated Circuit Amp 20 20 Voltage Volt/Hz 115/60 115/60 Compressor Power H/P 1/2hp 3/4hp Thermostat Type Dixell Dixell Pump Type Procon/ Totton Refrigerant Type R134a R134a Refrigerant amount Lbs 1.334 1.345 Width, in 25 25 Depth, in 20 20 Height, in 32 32 Lbs 130/150 144/163 Dimensions Weight (net/gross) Procon-100gl/hr, Ready for Procon-100gl/hr, Ready for an optional second pump an optional second pump 3