1. INSPECTION
Each shipment should be carefully checked against the bill of lading or packing slip. The shipping
receipt should not be signed until all items listed on the bill of lading have been accounted for.
Check carefully for concealed damage. Any shortage or damages should be reported to the
delivering carrier.
Damaged material becomes the delivering carrier’s responsibility, and should not be returned to the
manufacturer unless prior approval is given to do so.
Warning: This equipment contains a refrigerant which may harm the public health and
environment by destroying ozone in the upper atmosphere. Venting or release of certain
refrigerants to the atmosphere is illegal. Refrigerant recovery devices must be used when
servicing this unit. Consult your local codes for requirements.
Warning: Do not service this unit before disconnecting all power supplies.



2. INSTALLATION REQUIREMENTS:
Dedicated power line , 115v, 60Hz, 20 Amp
Recommended ambient temperature range 60F-90F
Adequate air circulation as follows:
- air condenser cannot be obstructed or covered in any way
- no filters allowed to be used with the unit
3. SPECIFICATION
Name
Unit
Part Number
EXTRA 1/2HP
EXTRA 3/4HP
EG-1/2P
EG-3/4P
Maximum Distance
Ft
up to 250'
up to 450'
Capacity, (evap 20F)
BTU/hr
3250
4415
Glycol tank capacity
Gal
15
15
Dedicated Circuit
Amp
20
20
Voltage
Volt/Hz
115/60
115/60
Compressor Power
H/P
1/2hp
3/4hp
Thermostat
Type
Dixell
Dixell
Pump Type
Procon/ Totton
Refrigerant
Type
R134a
R134a
Refrigerant amount
Lbs
1.334
1.345
Width, in
25
25
Depth, in
20
20
Height, in
32
32
Lbs
130/150
144/163
Dimensions
Weight (net/gross)
Procon-100gl/hr, Ready for Procon-100gl/hr, Ready for
an optional second pump an optional second pump
3