Download VarioMatch User Manual

Transcript
Advanced Energy®
Table 3-1. Physical specifications (Continued)
Description
Load coil
Specification
The load coil varies by VarioMatch product part
number on the number of turns, the number of possible
taps, and the default tap setting from the factory (A, B,
or C).
PN 69000001, 69000062, 69000226, 69002206,
69002207, 69002208: No load coil
PN 69000004, 69000018, 69000022, 69000023,
69000024, 69000025, 69000046, 69000114, 69000115,
69000214, 69000230, 69000227, 69000229, 69000032,
69000034, 69001207, 69001214: 2 turns, 3 taps,
default: B
PN 6900003, 69000036, 69000037, 69000080,
69000082, 69000116, 69000228: 2 turns, 3 taps,
default: C
PN 69000007, 69000041: 4 turns. 5 taps. default: B
Topology
Varies by VarioMatch product PN
PN 69002206, 69002207, 69002208: L match or
Gamma (Default: Gamma)
PN 69000001: Gamma
All other PNs: L match
ELECTRICAL SPECIFICATIONS
This section includes electrical specifications for VM 300, VM 700, VM 1000, and
VM 1500 products.
3-10
Specifications
57020080-00D