Transcript
Keep Alive Check Setting Factory Default Necessity Disable/Enable Disable Required Disable: Disable the check of TCP connection is still alive or not. Enable: BF-2300 automatically send a Ping request to peer per each 30 seconds, the TCP connection will be terminated if no response of Ping reply from peer. Max TCP Connection Setting Factory Default Necessity 1,2,3,4 1 Required The allowed TCP connections accept by BF-2300 simultaneously. It is usually used when user needs to receive data from different hosts simultaneously. When multiple hosts establish TCP connection to BF-2300 at the same time, it will duplicate serial data and transmit to all hosts. When data comes from Ethernet port, it is sent on first-in-first-out basis to serial port. TCP Client Destination IP Address1&Port Setting Factory Default Necessity E.g., 192.168.0.1 None Required 0 to 65535 50000 Required 18