4.2.3.2 Outer Pulldown Modules Sensors / Gusset Sensors
The outer pulldown module sensors for Teradyne Docking interfaces and gusset sensors for Intest dock
interfaces are the same item except of the label. These detect the presents of the peripheral plate. The tool
option button will fillin in the presents of that sensor being triggered.
4.2.3.3 Coarse Alignment Sensor
The coarse alignment sensor is only contained on the Teradyne Dock interface. The sensor provides the ability
to detect if the peripheral is close to interface. The tool option button will fillin in the presents of that sensor
being triggered.
4.2.3.4 CAM Sensors
The CAM sensors are used to determine the state the Intest Dock. Due to the manual capability of the intest this
is important for the control to identify the state. Below is the sensor output verse docking state diagram.
CAM 1
CAM 2
UNDOCK