Download Installation / Troubleshooting Manual
Transcript
Flow Homogenizer Can Replacement 1. Remove the old Flow Homogenizer can. A Claw type oil filter wrench, or pipe wrench may be needed. Aluminum Base 2. Remove the Brass Tube Subassembly and, Debris Screen, (If used) from the old can. Install them in new can. 3. Put a coating of grease on the new Flow Homogenizer’s rubber sealing washer. Tube Assembly P/N 4001-250-00 4. Clean the Aluminum base and put a coating of grease on the seal’s mating surface. 5. Place new Flow Homogenizer can on its Aluminum base. Turn until “Finger tight”. Rubber Sealing Washer 6. Using a band type oil filter wrench, carefully rotate the can until tight, approximately ¾ of a turn past finger tight. • ATTENTION Position a strip of rubber, (Bicycle tube or rubber glove) between the wrench and can. The rubber both increases friction and protects the can. Use caution as over-tightening will buckle or collapse the can. This is NOT a FILTER FloScan MOUNT WITH ARROWS UP Flow Homogenizer Can P/N 4001-199-03 5/14/2003 FloScan Instrument Company, Inc. 3016 NE Blakeley Street, Seattle, WA 98105 7000-144-01 Tel: (206) 524-6625 Fax: (206) 523-4961 email: [email protected] http://www.floscan.com