Download AS20150-180 Serial No
Transcript
Model 180 Valve Cam Position General Maintenance For correct operation the cam should be set to stop, the position at the point of each function. This is done at the factory and rotation checked at this time. However, resetting may be necessary from time to time should the unit fail to draw brine. Setting is simple, index piston to service position, (fully in) switch off power, loosen screw “A”, adjust cam to position shown above. Switch on power. AS20150-180 Page 22