Download Operating instructions
Transcript
FOCUS Switch on the control 1.2 Operation Having connected the compressor to the power supply and having switched on the main switch, if applicable, the version is displayed (if neither Auto Restart nor Remote control are parameterized) on which the name of the control, the name of the manufacturer and the version number are shown. First a parameter adjustment between basic module and TAN is performed resp. and if applicable the registration of connected and not yet registered additional modules. When this procedure has been finished the symbol for the OFF key ing. Press OFF key to acknowledge and exit the display. is flash- Otherwise – Auto restart and/or Remote-On-Off is activated: After the recurrence of the power supply (net power failure) the display shows a countdown, starting with the set Auto Restart time [s]. When this time is expired the compressor switches to Ready status and starts automatically, as soon as the prerequisites are fulfilled. In case faults occur when the compressor is powered up they are displayed immediately after the parameter reconciliation. The fault has to be acknowledged to get to the main display (see also section „1.7 Warning message/Fault message“, page 30). Switch on the compressor CAUTION: Risk of injury! If the compressor is not closed there is a risk of injury due to rotating or projecting parts resp. a crushing hazard because of flaps or doors standing open! The compressor may only be operated with all flaps and doors closed! At first OFF should be displayed in the bottom frame – the status display of the compressor. If EMERGENCY STOP is displayed for the compressor status the EmergencyStop button has to be unlocked first. If the status display shows Fault, the control is faulty and the malfunction has to be corrected first (see also section „1.7 Warning message/Fault message“, page 30). Once this has been accomplished and the display shows the OFF status the compressor can be put into the Ready status by pressing the ON key . A green LED signals that the compressor is ready for operation and the pressure control is active – as long as no "Timer-Off" is due or an external pressure control was parameterized. Ready Page 4 If the compressor status Ready is displayed, the compressor is in the "readyfor-operation" status. That means that the compressor automatically (re)starts pressure and/or time controlled – as long as the conditions to do so are fulfilled. BOGE FOCUS compressor control for screw compressors