Download Universal Expander Module INSTALLATION MANUAL
Transcript
Universal Expander Module. Installation Notes. 8 Revision 1.2 August. 2003. 5 Auxiliary Output Wiring 3000/Access 4000 Systems - Auxiliaries 1 & 2 can switch up to 500mA continuous, and are suitable for inductive loads. (Except for lock strikes, etc.) - Max current on any other individual Auxiliary must be less than 200mA. - Total current drawn by Auxiliaries + LAN + Detectors must be less than 700mA. (1.5A if optional 2.5A in-line transformer is used instead of plug pack AND Link JP1 shorted) - When an external power supply is used to power auxiliary devices, a good common Negative connection MUST exist between the power supply and the module. - Clamp diode should be fitted across inductive loads. Kathode (bar) to +ve. 2000 Systems SW1 LANKEY. Used to provide some security against the Expander Module being replaced with a substitute module. The 8 switches must be set to the same pattern as the LANKEY option set in the Control module during LAN configuration. If the setting of the 8 switches differs from the LANKEY the Expander will not be recognised. Choose a secret combination of the 8 switches that you will use for this installation. When you configure the system make sure the LANKEY option matches the switch settings. e.g. SW 1 2 3 4 5 6 7 8 On Off Off On On Off On On LANKEY settings: SW2 1-3 4 5 LAN key 1 2 3 4 5 6 7 8 Y Y Y Y Y Module Number. See details on page 9. Not used. Set to Off. AC Mains fail delay time. Off = 20 seconds On = 255 seconds 6 2000+ Module number. See details on page 9. 7 On = Invert Auxiliaries 1 to 4. 8 On = Invert Auxiliaries 5 to 8. Auxiliary outputs normally switch to ground when the Auxiliary is active, or On. SW7 and 8 are used to reverse the operation of the Auxiliary outputs so that the output will be switched to ground when the Auxiliary is Off and will float High when the Auxiliary is On. 1 .2 k Ω cu rren t lim it resisto r. + v e co nn ection s to + v e n earest the A ux . o u tp ut RELAY 1 .2 k SW2 Module number. See details on page 9. 5 6 7 AU X8 4 5 6 7 8 S ee n otes. A u x iliary C u rren t (A U X 2 to 8 ) < 2 00 m A p er A u x ilia ry. N o te L E D o rie ntatio n . Locks are activated via a relay. External power supply is used for lock power to prevent voltage spikes reaching the equipment, provide longer battery backup & minimise the possibility of earth loops. DET - 3 Expander type. See details on page 11. Input Debounce time. Off = 400mS (normal) On = 40mS (fast) AC Mains fail delay time. Off = 20 seconds On = 255 seconds On = Lift Mode. Set to On when Lift Interface board/s connected. Zones 1 to 8 External. (In Lift mode) Link JP5 must also be removed. Zones 9 to 16 External. (In Lift mode) Link JP2 must also be removed. Not used. Not used.- 7 A U X 8 D E T+ SW1 1 2 DET + DIPSwitch settings R e la y a n d L o c k p o w e r C o n n e c tio n s M U S T b e se p a ra te d . o NE G - o PO S + External Pwr Supply C la m p D io d e M U S T b e fitte d a c ro ss L o c k . K a th o d e to + v e . (Batt. backed)