Download Installation Manual
Transcript
FEATURE Menu Parameter Choices Description SOFTKEYS <blank> Time/Date Display Tare Display Accum Display ROC Setpoint Batch Start Batch Stop Batch Pause Batch Reset Weigh In Weigh Out Truck Regs Unit ID Select Scale F1–F10 Diagnostics Use the Add and Remove softkeys to select softkeys to be displayed in weighing mode. KYBDLK OFF ON Keyboard lock. Specify ON to disable the keypad in normal mode. ZERONLY OFF ON Zero key only. Specify ON to disable all front panel keys except ZERO in normal mode. PROMPTS PROMPT1– PROMPT60 Specify prompts for use in setpoint names. Prompts are referenced by the NAME parameter under the SETPTS submenus; prompts can be shown on the display during setpoint execution. REGULAT NTEP CANADA INDUST NONE OIML Regulatory mode. Specifies the regulatory agency having jurisdiction over the scale site. REGWORD GROSS BRUTTO Sets the term displayed when weighing in gross mode. Selecting BRUTTO replaces the Gross annunciator with Brutto. CONTACT — Allows specification of contact information for use in iQUBE alert messages. See Level 3 submenu descriptions in Table 3-7 on page 38. LOCALE OFF ON Locale. Set this parameter ON to enable the LATUDE and ELEVAT parameters. Specifying latitude and elevation of the scale site provides compensation for gravitational effects. Attached scales must be recalibrated after changing this parameter from OFF to ON. • OIML, NTEP, and CANADA modes allow a tare to be acquired at any weight greater than zero. NONE allows tares to be acquired at any weight value. • OIML, NTEP, and CANADA modes allow a tare to be cleared only if the gross weight is at no load. NONE allows tares to be cleared at any weight value. • NTEP and OIML modes allow a new tare to be acquired even if a tare is already present. In CANADA mode, the previous tare must be cleared before a new tare can be acquired. • NONE, NTEP and CANADA modes allow the scale to be zeroed in either gross or net mode as long as the current weight is within the specified ZRANGE. In OIML mode, the scale must be in gross mode before it can be zeroed; pressing the ZERO key in net mode clears the tare. • INDUST provides a set of subparameters to allow customization of tare, clear, and print functions in non-legal-for-trade scale installations. See Level 4 parameter descriptions in Table 3-8 on page 39. The value specified for this parameter affects the function of the front panel TARE and ZERO keys. See Section 10.2 on page 96 for a complete description of TARE and ZERO key functions for each of the regulatory modes. NOTE: Gravitational compensation settings do not affect iQUBE scales. Table 3-6. FEATURE Menu Parameters (Continued) 36 920i Installation Manual